Prestige Solo 175 User's Information Manual

Gad fired low pressure boiler

Advertisement

prestige
User' s Information Manual
WARNING
If the information in this manual is not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
Revised 8/31/06
FOR YOUR SAFETY
2004-3 Prestige User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Solo 175 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Prestige Solo 175

  • Page 1 - Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. 2004-3 Prestige User’s Manual Revised 8/31/06...
  • Page 2: Table Of Contents

    Table of Contents PRODUCT & SAFETY INFORMATION Page 1 Service and Maintenance PRESTIGE Operation Boiler & System Water SECTION I - Combustion Air - Prevention of Contamination Page 2 Potential Contaminating Products Areas likely to find these Products SECTION II - Maintenance Schedule...
  • Page 3: Product & Safety Information

    • The PRESTIGE is equipped with a low water cutoff device. The boiler and system piping must be filled and pressurized to 15 psig prior to startup. The unit will shut down if the pressure falls below 10 psig.
  • Page 4: Section I - Combustion Air - Prevention Of Contamination

    Hydrochloric acid / muriatic acid Cements and glues Antistatic fabric softeners used in clothes dryers Do not operate a PRESTIGE unit if its combustion air inlet or the unit is located in or near a laundry room Chlorine-type bleaches, detergents, and clean- or pool facility.
  • Page 5: Section Ii - Maintenance Schedule

    Clean heat exchanger and flue ways. PRESTIGE or in system components, resulting in severe personal injury, death or substantial Remove burner assembly and clean burner head property damage.
  • Page 6: Section Iii - Maintenance Procedures

    3. In addition does not allow the unit to operate correctly, con- to this maintenance, the PRESTIGE should be serv- tact your qualified service technician to inspect iced at the beginning of the heating season by a the unit and the vent / combustion air system.
  • Page 7: Monthly Maintenance

    Maintenance Procedures WARNING Monthly Maintenance Check Vent Piping Under some circumstances the PRESTIGE may not produce enough condensate to keep the condensate 1. Visually inspect the flue gas vent piping for any trap full of liquid. If the trap is not full, small...
  • Page 8: 6-Month Maintenance

    This discharge line must be installed by a qualified service technician or heating / plumbing installer in accordance with the PRESTIGE installa- tion manual. The discharge line must be terminated so as to eliminate possibility of severe burns or...
  • Page 9: Section Iv - Operations Instructions

    Follow the gas supplier’s instructions. OPERATING INSTRUCTIONS 1. STOP! Read the safety information above on 7. Turn the service switch on the PRESTIGE con- this label. This appliance is equipped with an trol panel “ON”. ignition device which automatically lights the 8.
  • Page 10: Section V - Boiler Control Display

    STANDBY mode as shown in the figure above. Burner ON for space heating (CH) This is the standard mode for the PRESTIGE. The con- trol automatically returns to this mode after 20 minutes if Burner ON for domestic water heating (DHW) no keys have been pressed on the display.
  • Page 11 Boiler Control Display SETTING THE BOILER PARAMETERS ACCESSING BOILER INFORMATION Information Mode Parameter Mode To switch from STANDBY mode to Information mode, press MODE twice. To access PARAMETER mode when the system is in Press STEP until the system displays the information STANDBY mode, press the MODE button once.
  • Page 12 Gas valve harness not properly connected For a detailed description of the error codes, reference Power supply lost after lockout occured the PRESTIGE Trouble Shooting Guide. Internal control failure WARNING Internal control failure Internal control failure...
  • Page 13: Replacement Parts

    Top Jacket Panel - Solo 110 PSJKT03T Top Jacket Panel - Solo 175/250 PSJKT02T Top Jacket Panel - Access - Solo 110 PSJKT04T Top Jacket Panel - Access - Solo 175/250 PSJKT03 Control Cover Panel PSRKT21 Wall Mounting Bracket with Hardware...
  • Page 14 Replacement Parts Fig. 3: Prestige Internal Components - Solo 110 Item Part No. Description PSRKIT01 Heat Exchanger Body PSRKIT02 Vent Outlet Adapter PSRKIT03 Combustion Air Inlet Adapter PSRKIT04 NTC Sensor (NTC1, NTC2 and NTC5) PGRKIT20 LWCO Pressure Device PSRKIT05 Condensate Drain Assembly...
  • Page 15 Replacement Parts Fig. 4: Prestige Internal Components - Solo 175/250 Item Part No. Description PSRKIT25 Heat Exchanger Body SOLO 175 PSRKIT26 Heat Exchanger Body SOLO 250 PSRKIT27 Vent Outlet Adapter PSRKIT03 Combustion Air Inlet Adapter PSRKIT04 NTC Sensor (NTC1, NTC2 and NTC5)
  • Page 16 Burner Head with Gasket - Natural - Solo 110 PSRKIT11 Burner Head with Gasket - Propane - Solo 110 PSRKIT31 Burner Head with Gasket - Propane - Solo 175/250 PSRKIT12 Burner Plate - Solo 110 PSRKIT32 Burner Plate - Solo 175/250...
  • Page 17 Replacement Parts Fig. 6: Prestige Electronic Components Item Part No. Description PSRKIT18 Prestige Control Module PSRKIT19 Transformer with Surge Protection PSRKIT20 Prestige Control Module Display PSRKIT17 Pressure Gauge - Not shown...
  • Page 18 Additional quality water heating equipment available from Triangle Tube/Phase III Heat Master Commercial Water Heaters Stainless steel construction Oil and Gas fired A unique design that eliminates the problem of associated with traditional water heaters Inputs ranging from 165,000 BTU/hr to 390,000 BTU/hr 5 year non-prorated warranty ASME version available Delta ELITE &...

This manual is also suitable for:

Solo 250Solo 110

Table of Contents