Prestige Solo Installation, Operating And Servicing Instructions

Prestige Solo Installation, Operating And Servicing Instructions

Wall-mounted condensing boiler

Advertisement

Quick Links

Serial number higher than 40000:
please see the new MCBA
parameters in
"Instruction for specialist MCBA-5"
664Y2300.C
Prestige
Installation, Operating and

Servicing Instructions

Prestige Solo
Prestige Excellence
EN • 1
MK2
24 - 32
24 - 32

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Solo and is the answer not in the manual?

Questions and answers

Summary of Contents for Prestige Solo

  • Page 1: Servicing Instructions

    Prestige Installation, Operating and Servicing Instructions Prestige Solo 24 - 32 Serial number higher than 40000: please see the new MCBA Prestige Excellence 24 - 32 parameters in "Instruction for specialist MCBA-5" EN • 1 664Y2300.C...
  • Page 2: Table Of Contents

    Installation of two heating circuits controlled by room thermostat ACV 15 and AM3-11 module Installation of two heating circuits controlled by Room Unit and ZMC-1 module Installation of a Prestige excellence or Prestige Solo + a DHW tank without hot water priority electrical connection...
  • Page 3: Warning

    WARNINGS Who should read these instructions • The parts may only be replaced by genuine factory parts. You will find a list of the spare parts and their reference number These instructions should be read by: ACV to the end of this document. - the specifying engineer - the installer •...
  • Page 4: Introduction

    3°C, the system automatically ignites ACV uses its BG 2000-M burner for the Prestige: this is an the burner until the temperature rises above 10°C. The pump air/gas premix burner providing safe and silent operation while continues to run for about 10 minutes.
  • Page 5 INTRoDuCTIoN prestige solo Chimney connection [concentric tubes Ø 80/125 mm] Burner, premix and modulating Pump, central heating Heat exchanger, stainless steel Electrical panel [The control boxes on the rear are optional] Flue tube Control panel prestige excellence Burner, premix and modulating Flue tube [concentric tubes Ø...
  • Page 6: Users Guide

    uSERS GuIDE directions for use Setting the domestic hot water temperature Your system must be checked once a year by an approved (Hot water temperature) installer or maintenance company. - Press Mode: The screen displays PARA. - Press Step: the first character is 1 and the last two characters Starting the burner give the current hot water temperature setting.
  • Page 7: Technical Characteristics

    TECHNICAL CHARACTERISTICS natural gas model Solo Excellence Central heating Max. Input 80/60°C Min. Input 80/60°C Max. output 80/60°C 23,4 23,4 Min. output 80/60°C Efficiency 30% load [EN677] Flue gases CO emissions max. / min. Input mg/kWh 45 / 20 52 / 20...
  • Page 8: Domestic Hot Water Features

    TECHNICAL CHARACTERISTICS propane model Solo P Excellence P Central heating Max. Input 80/60°C 30,5 30,5 Min. Input 80/60°C Max. output 80/60°C 23,4 29,6 23,4 29,6 Min. output 80/60°C Efficiency 30% load [EN677] Flue gases Flue gas pipe - Max. pressure drop Concentric flue gas channel maximum length Ø...
  • Page 9 Pressure drop on the heating side Pressure drop on the domestic hot water side for the Prestige Excellence A = Pressure drop of the boiler B = Pressure available (for the heating circuit) circulator on 1...
  • Page 10: Installation Instructions

    INSTALLATIoN INSTRuCTIoNS dimensions Solo Excellence A mm 1030 B mm C mm D mm E mm F mm G mm 1000 H mm boiler room ACCESSIBILITY - Make sure that all air vents are unobstructed any times. The appliance must be positioned in such a way to be - Do not store any flammable products in the boiler room.
  • Page 11 INSTALLATIoN INSTRuCTIoNS distances of hydraulic connections : solo A. Heating circuit supply 1” [F] B. Heating circuit return 1” [F] C. Supply to the water heater 1” [F] - With Kit DHW 10800079 D. Return from the water heater 1” [F] - with Kit DHW 10800079 E.
  • Page 12 B23P : Connection to an exhaust system of the combustion products designed to operate with positive pressure. - The Prestige has an inbuilt gas/air ratio regulator, which makes it largely independent of the pressure drop in the air intake and C13 : Connection by pipes with horizontal terminal units that flue gas extraction system.
  • Page 13 Options for connection to the chimney B23P C33s domestic hot Water connection prestige excellence The Prestige Excellence boiler can be connected directly on the Prestige Excellence domestic hot water circuit. Flush out the system before connecting the domestic hot water part.
  • Page 14 Optional accessories Code Description prestige Domestic hot water hydraulic kit Kit to connect a Prestige Solo boiler to an external water heater. The kit includes : - one circulator - one NTC sensor 12kΩ (L = 3,2 m) - one check valve...
  • Page 15: Connection To The Gas

    Make - The wall frame of the Prestige Solo is fitted with an integrated sure you prevent the freezing of the condensates.
  • Page 16 INSTALLATIoN installation of a simple heating circuit controlled by room thermostat acV 15 AF120 ACV 15 General diagram MCBA The On/Off room thermostat controls the central heating system (radiators or convectors). If an outside temperature sensor is connected, the boiler continuously adjusts its operating temperature depending on the outside temperature.
  • Page 17 INSTALLATIoN installation of a simple heating circuit controlled by room unit AF120 Room Unit General diagram MCBA A Room Unit controls the heating system (radiators or convectors). The unit allows the selection various central heating functions and can be programmed for up to 3 schedules per week, both for heating and hot water production.
  • Page 18 INSTALLATIoN installation of tWo heating circuit controlled by room thermostat acV 15 and am3-11 module AF120 ACV 15 MCBA General diagram AM3 - 11 This is a simple way to control two heating circuits (radiators or floor heating). You can adjust those two circuits depending on the outside temperature.
  • Page 19 INSTALLATIoN to be wired in accordance with the applicable regulations. Outside T° (°C) Factory typical Factory typical setting setting Description setting setting Description 00 : Heating mode “OFF” • Direct circuit : weather depending 01 : Heating mode “ON” controlled. The pump of the direct circuit is controlled by the room thermostat.
  • Page 20 INSTALLATIoN installation of tWo heating circuit controlled by control unit and Zmc-1 module AF120 Room Unit MCBA General diagram ZMC1 This configuration controls two heating circuits (radiators or floor heating). In addition, the Room unit features a remote monitoring of the two circuits You can adjust those two circuits depending on the outside temperature.
  • Page 21 INSTALLATIoN to be wired in accordance with the applicable regulations. AV MPK ZU AUF ZMC1 0 24V A B VF VE 10800036: Interface address “0” Factory typical setting setting Description 00 : Heating mode “OFF” 01 : Heating mode “ON” Setting T°...
  • Page 22 Enables communications between the MCBA and the Room Unit RSC. 10510100 outside temperature sensor 12kΩ — af120 Domestic hot water hydraulic kit : Kit to connect a Prestige Solo boiler to an external water heater. 10800079 Prestige Solo The kit includes :...
  • Page 23 INSTALLATIoN to be wired in accordance with the applicable regulations. AV MPK ZU AUF ZMC1 0 24V A B VF VE 10800036: Interface address “0” factury typical setting setting Description Domestic hot water temperature setting (to be adjusted between 60 and 80°C).
  • Page 24: Electrical Connection

    ELECTRICAL CoNNECTIoN EN • 24 664Y2300.C...
  • Page 25: Commissioning And Maintenance

    - Check that the safety valves are operating correctly. Prestige excellence: purge the primary circuit of the tank by - Drain the whole system and if necessary re-fill the appliance to means of the manual air vent on the top of the tank.
  • Page 26: Disassembling The Burner

    CommISSIoNING AND mAINTENANCE disassembling the exchanger disassembling the burner - Drain the water from the central heating system using the - Close the inlet gas valve. connection under the appliance. - Remove the front panel of the boiler. - Allow the appliance to drain completely. - Unplug the fan plugs (24 Volt), the ignition cable, the gas valve - Dismantle the electrical connections downstream from the control and the ignition electrode earth.
  • Page 27: Mcba Parameters For The Specialist

    mCBA pARAmETERS FoR THE SpECIALIST standby mode Once the cause of the blockage has been resolved, the burner starts automatically within 150 seconds at most. Standby Mode Status Boiler function After you power down the appliance the screen displays Pilot Internal check —...
  • Page 28 Pilot mode after 20 minutes and automatically enables the changes. Screen MODE Factory setting Screen Description of parameters Solo Excellence Adjusting the hot water temperature STEP 00 = Stop 01 = Start 02 = Stop + pump...
  • Page 29: Entering The Code

    mCBA pARAmETERS FoR THE SpECIALIST reQuest for information entering the code on the installation code mode info mode You can access the following parameters by entering the service code: To switch from Standby to Info mode, press Mode twice. • Parameters 5 - 42 Screen •...
  • Page 30: Mcba Parameters With Code Restricted Access

    FoR THE SpECIALIST mcba parameters With code restricted access Factory setting Screen Description of parameters Solo Excellence Minimum central heating temperature when using an outdoor sensor STEP Minimum outdoor temperature [adjust the heating curve] STEP Maximum outdoor temperature...
  • Page 31 FoR THE SpECIALIST Factory setting Screen Description of parameters Solo Excellence Prestige 32 natural gas Prestige 24 Max. number of revs natural gas in domestic hot water mode [rpm x 100] Prestige 32 STEP propane Prestige 24 propane...
  • Page 32 FoR THE SpECIALIST Factory setting Screen Description of parameters Solo Excellence Central Heating modulation hysteresis enabled STEP Central Heating modulation hysteresis disabled STEP Domestic hot water modulation hysteresis enabled STEP Domestic hot water modulation hysteresis disabled STEP Detection of domestic hot water hysteresis...
  • Page 33 FoR THE SpECIALIST Factory setting Screen Description of parameters Solo Excellence First position: Domestic hot water pump [1] or three-way mixer tap [2] Second position: STEP tank with NTC3 probe [2] or tank with thermostat (3) Manual fan number of revolutions...
  • Page 34 mCBA pARAmETERS FoR THE SpECIALIST communication mode [with code] error mode [with code] When in this mode, the system displays the communication ERROR mode indicates the most recent error, as well as the between the boiler and the control module, the optional interface status of the boiler and its readings at the time this error kit or the optional programmable room thermostat.
  • Page 35 mCBA pARAmETERS FoR THE SpECIALIST safety stop [error mode] To unlock the system: • Press RESET on the screen. If a fault occurs while the appliance is running, the system locks • Contact your installer if the fault happens again. and the screen starts to flash.
  • Page 36 mCBA pARAmETERS FoR THE SpECIALIST Codes Description of the fault Resolution of the fault - Check the connection of the NTC3 sensor - Check the wiring of the NTC3 sensor NTC3 short-circuit If the problem persists, replace the NTC3 sensor - Check the connection of the NTC1 sensor - Check the wiring of the NTC1 sensor NTC1 connection open...
  • Page 37 537D6184 537D6192 EN : Vertical outlet EN : Condensate recovery FR : Terminal vertical FR : Récupérateur de condensats NL : NL : Dakdoorvoer Condensopvang ES : ES : Terminal vertical Recuperador de condensados IT : Terminale verticale IT : Recuperatore di condensati DE : Senkrechte Dachdurchführung...
  • Page 38 557A6006 547D3021 EN : Non return valve EN : Transformer [230 Volt / 24 Volt] FR : Clapet anti-retour FR : Transformateur [230 Volt / 24 Volt] NL : NL : Terugslagklep Transformator [230 Volt / 24 Volt] ES : ES : Válvula anti-retorno Transformador [230 Volt / 24 Volt]...
  • Page 39 Centralina MCBA [Gas naturale] IT : Centralina MCBA [Gas naturale] DE : MCBA- Brennersteuerung [Erdgas] DE : MCBA- Brennersteuerung [Erdgas] Solo 24 Solo 32 EN : EN : MCBA burner control [Natural gas] MCBA burner control [Natural gas] 5476G016 5476G022...
  • Page 40 N° Side panel Latérale Zijkanten Lateral Laterale Seitenblech Front panel Face avant Frontstuk Parte delantero Pannello anteriore Vorderblech Top cover Couvercle supérieur Bovenkap Tapa superior Coperchio superiore Obere Abdeckung Rear panel Panneau arrière Achterpaneel Panel trasero Pannello posteriore Hinterblech Control panel Tableau Paneel Panel...
  • Page 41 Prestige Solo A03 : 21475419 A01 : 21471419 A06 : 21480069 A04 : 21474419 A02 : 21473419 A01 : 21471419 A05 : 54761008 A10 : 21476419 A09 : 2147E419 Prestige Excellence A03 : 21475420 A01 : 21471420 A06 : 21480069...
  • Page 42 N° Flue gas pipe Tube de fumées Rookgas pijp Tubo de humos Condotto fumi Abgasrohr Ø 80mm Ø 80mm Ø 80mm Ø 80mm Ø 80 mm Ø 80mm Heat Echangeur Intercambiador Scambiatore Warmtewisselaar Wärmetauscher exchanger de chaleur de calor di calore Tubo de salida del Exchanger Tube de départ...
  • Page 43 Prestige Solo B01 : 497B0031 B03 : 507F4086 B07 : 507F4083 B04 : 557A4014 B02 : 63962009 B05 : 507F4087 B11 : 507F4052 B06 : 557B4002 Prestige Excellence B11 : 507F4068 B01 : 497B0031 B16 : 507F4066 B08 : 30538481...
  • Page 44 C05 : 557A0012 C11 : 507F4096 C06 : 557A0048 C10 : 507F4095 C09 : 537DZ025 - 537DZ026 C07 : 51700061 C08 : 557A0058 Burner propane - Brûleur propane - Brander propaan Quemador propano - Bruciatore propano - Propangasbrenner Prestige Solo / Excellence...

Table of Contents