A. Chimney Requirements
When planning your fireplace location, the chimney con-
struction and necessary clearances must be considered.
The fireplace system and chimney components have
been tested to provide flexibility in construction. The fol-
lowing figures are the minimum distances from the base
of the fireplace.
•
Minimum overall straight height is 6 ft 4 in. if the
fireplace is freestanding and a minimum of 10 ft from a
combustible structure. See Figure 3.2.
•
Chimney must extend 2 ft (.6 m) above any portion of the
roof within 10 ft (3 m) of the chimney. Refer to Figure 6.1.
•
Minimum height width offset/return
•
Maximum height
•
Maximum chimney length between an offset
and return
•
Maximum distance between chimney
stabilizers
•
Double offset/return minimum height
•
Maximum unsupported chimney length
between the offset and return
• Maximum unsupported chimney height above
the fireplace
•
Minimum overall straight height if fireplace is
freestanding
Determine the chimney components needed to complete
your particular installation:
•
Measure the total vertical height of the fireplace
installation from the base of the fireplace assembly to
the approximate location of the bottom of the termination
cap.
•
Subtract the effective height of the fireplace assembly
(see Figure 8.2) from the total vertical height to determine
the overall height of the chimney installation.
•
Create a schematic for your application similar to Figure
8.2 showing components required (referring to Table
8.1). Figure 8.1 identifies those components and where
used.
•
Install a ceiling firestop whenever the chimney penetrates
a floor/ceiling.
NOTICE:
A maximum of two pairs of offsets and returns
may be used.
CAUTION! Risk of Fire and/or Asphyxiation! DO
NOT connect this fireplace to a chimney flue servicing
another appliance. DO NOT connect to any air distribu-
tion duct or system. These actions could cause over-
heating/fire in the chimney flue, or release of exhaust
fumes into the living areas.
24
Outdoor Lifestyles by Hearth & Home Technologies Inc.• 4072-137 Rev F • 11/25/13
ft
m
16
4.88
90
27.43
20
6.1
35
10.67
24
7.32
6
1.83
35
10.67
6.4
3.048
39 1/2 in. (1003 mm)
Effective Height
Figure 8.2
Table 8.1
HEIGHT OF CHIMNEY COMPONENTS
Chimney Stabilizer
SL3
Ceiling Firestops
FS338
FS339
FS340
Offsets/Returns
SL315
SL330
Roof Flashing
RF370
RF371
Chimney Sections*
SL306
SL312
SL318
SL324
SL336
SL348
* Dimensions reflect effective height.
20 ft (6.10 m) max.
pipe between an
offset & return
Ceiling Firestop
14.5 ft (4.42 m) min. height/single offset-return
20 ft. (6.1 m) min. height/double offset-return
Chimney Requirements
in.
mm
4-3/4
121
0
0
0
0
0
0
13-3/8
340
15-1/2
394
0
0
0
0
4-3/4
121
10-3/4
273
16-3/4
425
22-3/4
578
34-3/4
883
46-3/4
1187
6 ft (1.83 m) max.
unsupported chimney
above roof
35 ft (10.67 m)
max. straight
unsupported
chimney height
90 ft (27.43 m) max. height