Shrouds; Radiation Shield; Field Constructed Shrouds - Outdoor Lifestyles ODVILLA-36H Owner's Manual

Outdoor woodburning fireplace
Table of Contents

Advertisement

10

Shrouds

A. Radiation Shield
Some shrouds require a radiation shield. Use where
specified.
Radiation shield must be constructed of minimum 26 ga
sheet metal.
B. Field Constructed Shrouds
WARNING! Risk of Fire!
as specified. Improper construction may overheat chase
top.
Chase top shrouds may be field constructed where
permitted by regional building codes.
NOTICE:
Some regional codes require an agency-Listed
shroud. Consult your local building officials.
Hearth & Home Technologies Inc. supplies UL listed
shrouds. See your dealer for details.
The following field constructed shroud designs have
been tested for Hearth Technologies fireplace systems
and termination caps.
The shrouds must be constructed from a minimum .018
in. (26 ga) thick aluminized steel.
Open Top Shroud (TR342 caps require radiation shield)
Top Dim.
3 in (76 mm)
minimum
Min. Opening
Width
Min.
Base Dim.
Figure 10.2 Open Top Shroud Dimensions
34
Outdoor Lifestyles by Hearth & Home Technologies Inc.• 4072-137 Rev F • 11/25/13
Shrouds must be constructed
Min.
Top Dim.
Min.
Min.
Base Dim.
Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap
Figure 10.1 Radiation Shield
The wire mesh is optional but recommended and must
be .018 in. thick minimum, 1/2 in. mesh.
Min. Opening
Width
3 in. (76 mm) tall legs
Length x Width to fit inside shroud
TS345
TR342
Min. Base Dims.
23 x 23
28 x 28
in
mm
584 x 584
711 x 711

Radiation Shield

Required
Min. Top Dims.
in
20 x 20
25 x 25
mm
508 x 508
635 x 635
Min. Opening Width
in
17 x 17
22 x 22
mm
432 x 432
559 x 559
TR342/344TV
26 x 26
660 x 660
23 x 23
584 x 584
20 x 20
508 x 508

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Odvilla-36tOdvilla-42tOdvilla-42h