Red lead polarity:
Green = Monitor mode.
Green = B(-Ve).
Red = Talk Mode.
Red = Replace Battery
Red
= A (+Ve).
PULSE
FLASH
SPKR
VOL
?
LNR/PAUSE
MEM
STO
POL
1
2
3
4
5
6
7
8
9
0
#
TONE
TALK
MONITOR
MUTE
Warning!
When in Loudspeaker mode,
hold loudspeaker more than 30cm (1 foot)
from your ear.
Misuse can result in hearing damage.
DIALLING
DTMF/TONE is the default dialling mode.
p
PULSE Dialling
350/340
With the
connected to a live line,
p
t
press
PULSE
before selecting
mode. This is confirmed by a single high
beep. Dialling mode will automatically revert
to Tone when the line is disconnected or if
350/340
is switched off.
Mixed Pulse and Tone dialling
Select Pulse mode as above and dial the
*
Pulse digits. Press
(Tone) then dial the
Tone digits (the star will not be dialled out).
This can be stored in memory.
Storing a number in memory
S
r
STO
MEM
There are ten memory locations, one under
each of the dialling digits.
While connected to a line and in
TALK
mode:
S
Press
STO
to enter STORE mode.
r
Press
MEM
and a location (0-9).
Enter the telephone number to be stored.
S
Press
STO
to store.
ln memory you may also store
f
l
Flash
or
Pause
.
These will be
redialled as they were entered.
Dialling a number from a memory
location.
While connected to a line and in
TALK
mode:
r
Press
MEM then
the location digit 0-9.
The stored number under that button will be
redialled.
l
LNR/PAUSE: Last Number
Redial and Pause
l
Press
LNR/PAUSE
immediately after
off-hook to redial the previous number dialled.
l
In STORE mode press
LNR/PAUSE
insert a Pause in a memory. If within the first 5
entries, this inserts a 2 second pause in the
dialling out string, if not, then it halts the
l
dialling. Press
LNR/PAUSE
to resume.
f
FLASH
A timed line break is generated when the
f
FLASH
button is pressed.
P
POL: POLARITY TEST
P
Press
POL
and observe the polarity
LED.
RED
LED: red lead is connected to A (+Ve).
GREEN
LED: red lead is connected to B(-Ve).
Talk
350/340
During this test, the
impedance and will not interfere with data or
speech calls.
s
SPKR: SPEAKER MODE
s
Press
SPKR
to activate and deactivate
the hands-free function. If
350/340
pressed while the
speaker Monitor is automatically activated.
v
Press and release
VOL
receive volume setting, press again to return
to the normal setting.
In TALK mode, receive only is possible while
in speaker mode.
t
After disconnection from the line for more
350/340
than 5 minutes, the
switches off to preserve the battery, and the
time-out tone is heard.
*
,#,
Ground-start lines
On units fitted with optional third wire
(item M0023/15):
connect green wire to
t
ground, press TALK momentarily and check
for dial tone. Ground start is then automatic
and the green wire can be left connected to
t
ground, without affecting the call.
ELR: Earth Loop Recall
On units fitted with optional third wire
(item M0023/15):
while in TALK mode on a
looped line and with the green wire to ground,
p
press
PULSE momentarily and check for
second dial tone.
M
to
MUTE
M
Press and release
MUTE
transmission.
Press again to talk.
t
TALK MODE
t
Press
TALK
A double beep is heard and the mode LED
flashes
RED
.
m
Press
MONITOR
remains high
mode LED then flashes
PLEASE NOTE
to an overvoltage or a digital signal (350 only),
350/340
then the
sounds an alarm.
AUTOMATIC PROTECTION OF
s
SPKR
is
DIGITAL LINES:
is off, then Loud-
350/340
Connect the
Press and release
to select the high
DigAlert
Thanks to
cases:
1\ (350 only)A digital signal is present:
tone alarm
is heard,
and does not loop the line. To override this
alarm, hold down the
2\ A high DC level is present (>116V±4V):
single tone alarm
automatically
locks out and does not loop the line. This
alarm may not be overridden.
3\ A dc level between 76V(±4V) and
116V(±4V) is present:
heard, the mode LED flashes
350/340
GREEN
, the
loop the line. To override this alarm, press
t
TALK
again.
4\ No alarm (i.e. no digital signal nor high DC
present): the
loops the line.
Digital signal detection OVERRIDE
DigAlert 350
(
only
When connected to normal DC, it is possible to
override the digital detection lock-out by pressing
tTALK
and holding
until the override tones have stopped. This can be
particularly useful on a faulty line being highly
imbalanced.
m
MONITOR MODE
m
Press
MONITOR
GREEN
. Press again
350/340
off the
In order to extend its battery life, Monitor is
to cut off
automatically switched off after 20 minutes, if
connected to a powered line, and 5 minutes
after disconnection. An audible signal is
heard on timing out.
to go off-hook.
to go back on-hook. The
GREEN
.
350/340
: if the
is connected
does not loop the line and
to the line.
t
TALK
to go off-hook.
TM
, there are four different
a two
DigAlert 350
locks out
t
TALK
key.
a
350/340
is heard, the
a single tone alarm
is
RED and
locks out and does not
350/340
goes off-hook and
)
for more than 6 seconds and
(high Z).
. The mode LED flashes
m
MONITOR
to switch
.
Need help?
Do you have a question about the DigAlert 350 and is the answer not in the manual?