Ventilation Speed - A-TOUCH W-Thermo Instruction Manual

Table of Contents

Advertisement

moment you change the temperature, then the new temperature is stored in all
active periods, regardless of if they were different or not.
To adjust the temperature, proceed as follows:
16:41
22º
21.2º
TEMP. 23º
16:41
23º
21.2º
16:42
22º
TEMP. 22º
16:42
22º
21.2º

VENTILATION SPEED

The unit types AIRFLOW2, AIRFLOW4, AIR-CON1, AIR-CON2 and DAIKINFD have
ventilation and their speed is controlled by the thermostat.
When you switch on the thermostat, the ventilation speed is always set to
automatic. In this mode, the ventilation speed depends on the difference between
the target temperature and the room temperature: the higher the difference, the
higher the ventilation speed.
You can choose a certain ventilation speed. However, if you do it then the speed
will remain as you specified, regardless of the difference between target and room
temperature (manual mode).
To change the ventilation speed proceed as follows:
V1
22º
21.2º
V2
22º
21.2º
Notes:
-
The AIRFLOW4 unit type only has 2 speeds, all others have 3 speeds.
-
The transition between one speed and the next has a pause of about 1
second. This is necessary to avoid relay damage in some kinds of
ventilators.
info@a-touch.in.th
Press the key
(UP) to increase the temperature:
- the target temperature is shown temporarly on the big display and
then goes back to the normal display.
Press the key
(DOWN) if you want to decrease the temperature:
- the target temperature is shown temporarly on the big display and
then goes back to the normal display.
Press the key
(VENT) to select the next speed:
- the new speed is shown on the top left corner.
www.a-touch.in.th