Function
Range
Resistance
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
Capacitance
40nF
400nF
4μF
40μF
400μF
4000µF
40mF
Frequency
40Hz
(electronic)
400Hz
4kHz
40kHz
400kHz
4MHz
40MHz
100MHz
Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and <100kHz; 5Vrms
min @ 20% to 80% duty cycle and > 100kHz.
Frequency
40.00HZ-4KHz
(electrical)
Sensitivity:5Vrms
Duty Cycle
0.1 to 99.90% 0.01%
Pulse width: 100µs - 100ms, Frequency: 5Hz to 150kHz
Temp
-58 to 1382°F 0.1°F
(type-K)
-50 to 750°C
4-20mA%
-25 to 125%
0mA=-25%, 4mA=0%, 20mA=100%, 24mA=125%
Note: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.
Resolution
±(0.3% reading + 9 digits)
0.01Ω
0.0001kΩ
0.001kΩ
±(0.3% reading + 4 digits)
0.01kΩ
0.001MΩ
±(2.0% reading + 10 digits)
0.001MΩ
0.001nF
±(3.5% reading + 40 digits)
0.01nF
0.0001μF
±(3.5% reading + 10 digits)
0.001μF
0.01μF
0.1µF
±(5% reading + 10 digits)
0.001mF
0.001Hz
0.01Hz
0.0001kHz
±(0.1% reading + 1 digits)
0.001kHz
0.01kHz
0.0001MHz
0.001MHz
0.01MHz
0.01HZ to
0.001KHz
±(1.2% reading + 2 digits)
±(1.0% reading + 4.5°F)
±(1.0% reading + 2.5°C)
0.1°C
(probe accuracy not included)
0.01%
16
Accuracy
Not specified
±(0.5% reading)
±50 digits
EX540-EN V1.2 7/10