Lennox BRENTWOOD SP Installation And Operation Instructions Manual

Lennox BRENTWOOD SP Installation And Operation Instructions Manual

Epa wood-burning fireplaces

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it
is recommended that this appliance be fitted
with a Firescreen kit. See Page 20 for ordering
information.
WARNINGS
Listed to standards:
ULC-S610 & UL-127
Report No. 3011202
EPA Cert. No. 537
INSTALLATION AND

OPERATION INSTRUCTIONS

BRENTWOOD™
EPA Wood-Burning Fireplaces
P/N 850,039M REV. C 09/2007
MODEL
BRENTWOOD SP
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
Lennox™ wood-burning fireplaces are designed for use as a supple-
mental heater. They are not intended for continuous use as a primary
heat source.
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
• The fireplace cannot be operated without a door.
Consult your dealer to select the correct door
model.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
PIBRENTW REV. 8
WARNINGS
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRENTWOOD SP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lennox BRENTWOOD SP

  • Page 1: Operation Instructions

    Lennox™ wood-burning fireplaces are designed for use as a supple- mental heater. They are not intended for continuous use as a primary heat source.
  • Page 2: Safety Rules And Specifications For Mobile Or Manufactured Home Installation

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY NEVER use gasoline, gasoline- Never modify or alter your fireplace RULES BEFORE YOUR FIRST FIRE. type lantern fuel, kerosene, system in any way. To do so may charcoal lighter fluid, naphtha, create a potential fire hazard and WARNING engine oil or similar liquids to...
  • Page 3: Table Of Contents

    CONGRATULATIONS! OPERATING THE BRENTWOOD In selecting this LENNOX wood-burning appliance you have chosen one of the finest Fuel fireplaces available. The Brentwood™ is a clean burning EPA certified fireplace that is USE SOLID NATURAL WOOD FUEL ONLY. designed to provide you dependable service as well as warmth and enjoyment for many The Brentwood is designed to work best when years to come.
  • Page 4: Combustion Control

    Building a Fire Creosote may accumulate on the glass door. Push to Close This method of burning should be used only Air Boost To start a fire, place several crumpled up balls of after operating the Brentwood with the air newspaper in the firebox.
  • Page 5: Important Cautions

    B. Fans operating (e.g.: range hood) If the creosote accumulation is large, a creosote These fans draw air out of the house and fire in the chimney can damage the chimney may actually cause a negative pressure in the and overheat the surrounding wood framing. house.
  • Page 6: Refractory Installation

    “tight” in all areas, since a small amount of leakage is not Door Installation hazardous or detrimental to the performance of your fireplace. WARNINGS • Use only a Lennox Hearth Products glass doors, specifically designed for the Brentwood fire- place. • The fireplace cannot be operated without a door.
  • Page 7: Glass Care - Replacement

    F [260° C] is suitable) or adhesion problems may result. Apply gasket cement to the gasket channel and install the new gasket. This replace- 45” Min. 45 Deg. ment part is available from your Lennox Hearth Products dealer in the 4” following dimensions: Hearth 36”...
  • Page 8: Framing, Facing And Mantel

    940 mm Notes D. WARNING: The fireplace 30-1/8” 765 mm must not be in contact with Due to Lennox' ongoing commit- ment to quality, all specifications, any insulation or loose filling 13-1/2” 343 mm ratings and dimensions are subject material. Cover the insulation to change without notice.
  • Page 9 Insulated Chase Construction Insulate Joists Storm Collar Same As Ceiling Roof Support Flashing Floor Attic Radiation Ceiling Shield Wall Draft Stops Firestop Note: Floor and wall below the attic must be • Must have the same firestopping resistance CTDT insulated using the same insulation. as adjacent wall.
  • Page 10: Hot Air Ducting Installation

    HOT AIR DUCTING INSTALLATION For safe installation, the gravity kit must meet the following requirements: Frame Grille The Brentwood™ is approved for use with a Minimum height* 68” (1,727 mm) Gravity Kit. Maximum length See Figures 13 & 14 Gravity Kit * The height of the louver must be measured The gravity kit is designed for double hot air from the base of the Brentwood to the middle...
  • Page 11 Outlet Grill WARNING: The outlet grills should not be installed fac- ing upward through a floor. Danger of burns can result if grills in floor are stepped 10’ Max. 13” x 13” Outlet Grill 10’ Max. Maintain at least 6-1/2” (160 mm) clearance from the outlet grill framing to a combustible ceiling,...
  • Page 12: Outside Air Kit

    Carefully Brentwood™ hot air exhaust. push the insulation and plastic cover back over the pipe. Using aluminium tape, fasten the plastic 7. Use only Lennox Hearth Products grills and cover in place. components as described in this manual.
  • Page 13: Chimney System

    If interior installation is impossible, install an AC chimney enclosed in an insulated chase. two (2) feet Min. 2. The fireplace model Brentwood SP may be installed only with Security ten (10) feet three (3) feet Min.
  • Page 14: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- Attic Radiation Shield TIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, floor Solid Packed Pipe Flashing and roof where the chimney will pass (see Figure 18). Use a plumb-bob to line up the center of the holes.
  • Page 15: Offset Chimney Installation

    2. Install the necessary chimney lengths to Minimum Chimney Height Using Elbows achieve the required offset. Lock the chimney Fireplace Model Brentwood SP lengths together. If penetrating a wall, use a wall radiation shield. Chimney Model ASHT / S2100+ / HT6103+ / HT6000+ / AC 3.
  • Page 16 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 17: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Support Note: 45º angle for Canada only ( RSMI45) ACRS In cold climate locations (climates where temperatures will fall below 32°...
  • Page 18: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION CHIMNEY CHASE AND MULTIPLE TERMINATIONS For the purpose of this manual, a chimney chase is considered a part of Universal Roof Support the chimney system rather than part of a building. The termination must This support has three possible uses: be placed a minimum of 18”...
  • Page 19: Masonry Application Instructions

    Follow these steps: INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION 1- Position the fireplace in its location. Temporarily install the ASHT WARNING: Before starting the installation, the masonry chimney elbow on the top of the fireplace and, using a level, mark with an oval must be inspected by a qualified sweep.
  • Page 20: Installation Accessories

    Storm Collar, 6FC (for use with TUBINOX liner) Notes: Fireplace Model Brentwood SP - Approved Venting Components manu- N ova Temp HT6000+ is equivalent to Secure Temp S-2100+ factured by Security Chimneys International only. N ova Temp HT6103+ is equivalent to Secure Temp ASHT •...
  • Page 21 CHIMNEY - PARTS AND COMPONENTS LISTS (AC) Air-Cooled Chimney System* TUBINOX LL Chimney Lining System Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6” Diameter 6” I.D. & 11” O.D. Air Cooled, Stainl. Steel inner & zinc coated steel exterior Listed to ULC-S635M, UL-1777 &...
  • Page 22: Replacement Parts

    Secondary Air Tube PR-SR2271 Cast-iron Log Retainer Supports - Grate (2) PR-SR2324 CLEARANCE TO COMBUSTIBLES Cast Iron Log Retainer Bar (w/Lennox Logo) PR-SR2323 The following clearances meet the minimum requirements for a safe Touch-up Paint, Aerosol, Black Metallic SBMB6309 90L73 installation: Louvers, Upper &...
  • Page 23: Warranty

    HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this Warranty to be valid, LHP must be notified of the claimed defect in writing to Lennox Hearth Products, attention Customer Service Department, 1110 West Taft Avenue, Orange, CA. 92865, as soon as reasonably possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.
  • Page 24: Product Reference Information

    6. The installation date of the appliance. about your fireplace. Please contact your Lennox Hearth Products dealer for any questions or concerns. For the number of your nearest Lennox If you encounter any problems or have any questions concerning the Hearth Products dealer, please call 1-800-9-LENNOX.

Table of Contents