Lennox Brentwood LV Installation And Operation Instructions Manual
Lennox Brentwood LV Installation And Operation Instructions Manual

Lennox Brentwood LV Installation And Operation Instructions Manual

Epa wood-burning fireplaces

Advertisement

Quick Links

Shown with louver kit installed
THIS UNIT REQUIRES THE INSTALLATION OF A
FINISHING KIT. SEE "PARTS REQUIRED"
SECTION FOR DETAILS
Fireplace, Also For Use In
Manufactured Homes With Solid Fuel Only.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
an adjustable safety gate or barrier screen.
Shown with clean face kit installed
WARNINGS
Listed to standards:
ULC-S610 & UL-127
Report No. 3011202
EPA Cert. No. 537
PIBRENTLV REV. 1 02/2011
INSTALLATION AND

OPERATION INSTRUCTIONS

Brentwood™ LV
EPA Wood-Burning Fireplaces
P/N 506023-13 REV. A 02/2011
MODEL
Brentwood LV
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
Lennox Hearth Products wood-burning fireplaces are designed for use
as a supplemental heater. They are not intended for continuous use
as a primary heat source.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNINGS
• The fireplace cannot be operated without a door.
Consult your dealer to select the correct door.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Brentwood LV

  • Page 1: Operation Instructions

    THIS UNIT REQUIRES THE INSTALLATION OF A result in an unsafe and potentially dangerous installation. FINISHING KIT. SEE “PARTS REQUIRED” Lennox Hearth Products wood-burning fireplaces are designed for use as a supplemental heater. They are not intended for continuous use SECTION FOR DETAILS as a primary heat source.
  • Page 2: Safety Rules And Specifications For Mobile Or Manufactured Home Installation

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Always ensure that the air inlet to RULES BEFORE YOUR FIRST FIRE. treatments for windows located the fireplace is free from debris near the fireplace. Avoid using and any other obstructions that combustible flowing window can block the entrance of air.
  • Page 3: Table Of Contents

    - Louver kit Thank you for selecting a Lennox Hearth Products wood fireplace as the answer to your - Clean face obstruction plate kit. Must be home supplemental heating needs.
  • Page 4: Operating The Fireplace

    Primary Air and Air Boost Controls This will help cure the refractory bricks. During Fuel There is no flue damper in the Brentwood LV the first few fires of this appliance there may fireplace. As is common with air tight stoves, be some odor and smoke due to the curing of USE SOLID NATURAL WOOD FUEL ONLY.
  • Page 5: Refueling For Best Performance

    Your in this manner. Small dry pieces of softwood dealer can help you determine if you have The Brentwood LV fireplace will operate best if and construction scraps will burn very intensely properly seasoned wood for burning.
  • Page 6: Maintaining Your Brentwood™ Lv Fireplace

    MAINTAINING YOUR BRENTWOOD™ LV Dealing With a Chimney Fire Top Baffle Removal Prior to Cleaning The FIREPLACE Chimney Regular chimney maintenance and inspection Before starting to clean your chimney, we can prevent chimney fires. If you have a chimney Creosote - Formation and Need for Removal recommend that you remove the top baffle to fire, follow these steps: When wood is burned slowly, it produces tar...
  • Page 7: Refractory Installation

    WARNINGS If the fit is still not perfect, you can adjust the door using the hinge screws. • Use only a Lennox Hearth Products glass doors, specifically designed DOOR ADJUSTMENT for the Brentwood™ LV fireplace. The door may need to be adjusted to be com- •...
  • Page 8: Glass Care - Replacement

    Lennox Hearth Products dealer in the following UNIT WITH CRACKED OR BROKEN GLASS. dimensions: The Brentwood LV fireplace may be installed Glass Cleaning directly on the floor or on a raised base (for The Brentwood LV fireplace is designed to...
  • Page 9: Installing The Finishing Kits

    INSTALLING THE FINISHING KITS The gravity kit MUST BE used with the trim and the right side frame. This can be difficult because these are close together to clean face kit to allow hot air flow that allow a good look when using the louver kit. would normally come out of the top louver.
  • Page 10: Framing, Facing And Mantel

    Cover the insulation with Drywall panels around the fireplace. Hearth Extension Requirements 12” Max. The Brentwood LV fireplace may be installed (305mm) directly on a combustible floor. The supplied Mantel safety metal strip must be positioned as follows:...
  • Page 11: Fireplace And Framing Dimensions

    Corner Installation Back Wall of Chase/Enclosure Combustion OUTSIDE CHASE Including Finising Materials if any Air Kit 21-1/2” 20-3/8” Rough Framing Face (Unfinished Shown) * Zero Clearance From Back Spacer to Wall FRAMING DIMENSIONS 36-1/4” 921 mm Combustible materials can NOT be used in the space 2”...
  • Page 12: Insulated Chase Construction

    Insulate Joists Insulated Chase Construction Same As Ceiling Storm Collar Roof Support Flashing Draft Stops Attic Radiation Shield Floor Ceiling Firestop NOTE: It is recommended that the chase Wall walls and floor be insulated in the same CTDT Termination manner, using the same insulation, as the rest of the building, below the attic.
  • Page 13: Facing / Mantel

    Facing Non-Combustible Facing Fireplace Frame Section (Top View) The facing installation method depends on your Drywall finishing kit choice. 2” X 3” Min. 1. Facing with the louver kit - The 2x3 framing (51mm x 76mm) must offset to the back by a distance equiva- Spacer lent to the thickness of your facing material Rockboard...
  • Page 14: Hot Air Ducting Installation

    See Figures 20 and 21 * The height of the louver must be measured 45” Min. from the base of the Brentwood LV fireplace to (1143mm) the middle point of the louver. To extend the double outlet system forward of...
  • Page 15: Central Forced Air Kit

    Adaptor and not double wall as is required for the Brentwood™ LV fireplace hot air exhaust. Insulated 7. Use only Lennox Hearth Products grills and Flexible components as described in this manual. pipe Other grills or registers, for example, may be too restrictive and may overheat the fireplace or ceiling.
  • Page 16: Outside Air Kit

    OUTSIDE AIR KIT - REQUIRED (Included w/fireplace) OUTSIDE CONNECTION During operation, the fireplace requires fresh air for combustion and draws air out of the house. It may starve other fuel burning appliances such as gas or oil furnaces. As well, exhaust blowers may compete for Aluminum Tape air, causing negative pressure in the house, resulting in smoke entering Outside...
  • Page 17: Chimney System

    AC chimney enclosed in an insulated chase. 9. Cut and frame square holes in all floors, ceilings, and roof that the 2. The fireplace model Brentwood LV may be installed only with Security chimney will go through to provide a 2” (50 mm) clearance between Chimneys International Ltd 6”...
  • Page 18: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- Attic Radiation Shield TIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, floor Solid Packed Pipe Flashing and roof where the chimney will pass (see Figure 28). Use a plumb-bob to line up the center of the holes.
  • Page 19: Offset Chimney Installation

    If penetrating a wall, use Minimum Chimney Height Using Elbows a wall radiation shield. Fireplace Model Brentwood LV 3. Use another elbow to turn the chimney Chimney Model ASHT / S2100+ / HT6103+ / HT6000+ / AC vertically. Lock it to the chimney. Fasten...
  • Page 20 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 21: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Support Note: 45º angle for Canada only ( RSMI45) ACRS In cold climate locations (climates where temperatures will fall below 32°...
  • Page 22: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support 18” (460 mm) 18” (460 mm) When installing a support, slightly lift the chimney system so the weight will lie on the support, not on the fireplace to reduce expansion noises. This support has three possible uses: 1.
  • Page 23: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1- Position the fireplace in its location. Temporarily install the ASHT WARNING: Before starting the installation, the masonry chimney elbow on the top of the fireplace and, using a level, mark with an oval must be inspected by a qualified chimney sweep.
  • Page 24: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Fireplace Kits Description Cat./Part No. Description Cat./Part No. Blower motor speed control (wall mount), VRUW VRUW Finishing Kits (Required - Order Separately) Masonry Chimney Adaptor, 30º, BISUMA30 Louver kit LOUVRECF BISUMA30 (for use with TUBINOX liner) Central Forced Air Kit Accessories Clean face kit CAPPINGCF...
  • Page 25: Chimney Components Lists

    CHIMNEY - PARTS AND COMPONENTS LISTS Fireplace Model Brentwood LV - Approved Venting Components manu- factured by Security Chimneys International only. Secure Temp ASHT 1” High Temp. Insulated Stainless Steel Chimney • 6” diameter chimney - AC (air cooled), Secure Temp™ ASHT (or 6”...
  • Page 26 CHIMNEY - PARTS AND COMPONENTS LISTS (AC) Air-Cooled Chimney System* TUBINOX LL Chimney Lining System Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6” Diameter 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior Listed to ULC-S635M, UL-1777 and ULC-S640M at 2100º...
  • Page 27: Specifications

    SPECIFICATIONS CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe Cat. No. Model installation: H8295 Brentwood™ LV Side wall: 24” (610 mm) measured from the fireplace side. Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace. Product Reference Information Fireplace enclosure: Weight...
  • Page 28: Replacement Parts

    PR-SR2324 Cast iron log retainer bar PR-SR2323 Contact an Authorized Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials not approved by Lennox Hearth Products. Use of non-approved parts can result in poor perfor- mance and safety hazards.
  • Page 29 REPLACEMENT PARTS - BRENTWOOD™ LV NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 30: Product Reference Information

    Your Dealer's Name _________________________________________________ Your Dealer's Phone Number __________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

Table of Contents