External Control; About The External Control - JVC DT-V20L3D Instructions Manual

Multi format lcd monitor
Hide thumbs Also See for DT-V20L3D:
Table of Contents

Advertisement

External Control

7 About the external control

This monitor has three external control terminals.
• MAKE/TRIGGER terminal (RJ-45): The following external control systems are available.
(1) MAKE (make contact) system: Controls the monitor by short-circuiting the corresponding pin terminal to
the GND pin terminal, or disconnecting (opening) it.
(2) TRIGGER (trigger) system: Controls the monitor by sending the pulse signal instantaneously to the
corresponding pin terminal.
☞ "Using the MAKE/TRIGGER system" on page 17
• RS-485 terminals (RJ-45): Controls the monitor with the RS-485 system. (☞ "Using the serial communication"
on page 18)
• RS-232C terminal (D-sub 9-pin): Controls the monitor with the RS-232C system. (☞ "Using the serial
communication" on page 18)
Set the following items of "REMOTE SETTING" in SET-UP MENU according to the external control terminal and
control system (☞ "SERIAL TYPE", "PARALLEL TYPE" on page 15).
Control terminal
Control system
MAKE/TRIGGER
MAKE
terminal
TRIGGER
RS-485 terminal
Serial
communication
RS-232C terminal
1
*
For a monitor connected to a personal computer etc, select the terminal the equipment is actually connected to. For
other monitors, select "RS485."
The settings of this unit
"SERIAL TYPE" setting
"PARALLEL TYPE" setting
RS-485
RS485*
1
RS-232C
RS232C*
1
Control priority is as follows.
MAKE > TRIGGER = serial communication = buttons and menu on the monitor
• You can use the external control even when "CONTROL LOCK" is set to "ON" (☞ page 15).
• When the monitor is off (on standby), external control is not available. But certain external controls (starting/
terminating communication, turning on the monitor) are available through the serial communication (☞ page 18).
<MAKE/TRIGGER system>
You can control the monitor by a personal computer or dedicated controller*
• For the details, see page 17.
*
2
The controller is not commercially available. Consult your dealer if you need it.
<Serial communication>
PC, etc.
RS-485 IN
MAKE
or
RS-232C
TRIGGER
• For the details, see page 18.
2
.
RS-485
RS-485
RS-485
RS-485
OUT
IN
OUT
IN
16
RS-485
OUT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dt-v24l3d

Table of Contents