POWER CABLE CONFIGURATION

A mains cable is supplied with an IEC moulded socket at one end and a moulded mains plug, appropriate to the country of
use, at the other end. Where the moulded plug is fitted with a mains fuse, always replace with the same 5A rated fuse. If the
fitted plug is unsuitable for your type of power sockets, it should be cut off and disposed of safely ensuring that it cannot be
mistakenly inserted into a live socket.
The wires in the mains cable are coloured in accordance with the following code:
Green and Yellow
Blue
Brown
The internal wires of the mains cable may not correspond with the coloured markings identifying the terminals in your mains
plug, if that is the case then please proceed as shown below. Ensure that the terminals are tightened securely, and that no loose
strands of wire are present.The cord grip is clamped over the outer sheath of cable, rather than over the wires.
Green and Yellow must be connected to the terminal in the plug marked by the letter E, the earth safety symbol, or
coloured Green or Green and Yellow.
Blue must be connected to the terminal in the plug marked by the letter N or coloured Black.
Brown must be connected to the terminal in the plug marked by the letter L or coloured Red.
IMPORTANT - THIS EQUIPMENT MUST BE EARTHED.

FUSE PROTECTION

Additional mains fuses are provided in the voltage selector section of the IEC mains module. These can only be accessed once
the power supply cable has been unplugged. Fuses must only be replaced with those of the same type and rating. Anti-surge
type with spiral-wound element is recommended.
• For 100V - 120V use 5mm ( ") x 20mm ( ") Time Delay rated at 3.15A (T3.15A).
• For 200V - 240V use 5mm ( ") x 20mm ( ") Time Delay rated at 1.6A (T1.6A).
FOR YOUR OWN PROTECTION
• Store the complete packaging in case it is needed for re-use.
• Never expose the unit to moisture, water and extremes of temperature or humidity. Specifically, the unit shall not be exposed
to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the unit. Allow 150mm (6")
behind the unit to allow for sufficient ventilation. Efficient ventilation must not be impeded.
• Never remove the rear panel of the unit, as there is a risk of electric shock.
• There are no user serviceable parts inside the unit. Always refer servicing to your Tannoy dealer or authorised service agent.
• Avoid violent shocks to the unit during packing or transportation.
• Do not plug the unit into the mains until all other connections have been made and checked.
• Terminals marked with the flash symbol are hazardous live and the external wiring connected to these terminals requires
installation by an instructed person or the use of a ready-made lead or cord.
Earth
Neutral
Live
3
/
1 3
/
1 6
16
3
/
1 3
/
1 6
16
5