Vor/Ils Indicator (Gns 430W Only); Vor/Ils Indicator Function; Vor/Ils Indicator Electrical Characteristics - Garmin GPS 400W Installation Manual

Gns 400w series
Hide thumbs Also See for GPS 400W:
Table of Contents

Advertisement

4.8

VOR/ILS Indicator (GNS 430W Only)

4.8.1

VOR/ILS Indicator Function

Because the GNS 430W includes a ―CDI‖ button that performs switching between GPS
and VOR/ILS on a remote indicator, it is seldom necessary to use these outputs to drive
an indicator. It is only necessary when it is desired for a separate indicator to display
VOR/ILS deviation full-time (regardless of the ―CDI‖ button status).
The VOR/ILS indicator displays both lateral and vertical, To/From indications, lateral and vertical flags
and superflags. GNS 430W connector P4006 always outputs the VOR/Localizer/Glideslope navigation
information. The VOR/ILS pins on GNS 430W connector P4006 are used to drive an indicator that
displays VOR/ILS information at all times, regardless of the CDI selection on the GNS 430W.
VOR/LOC COMPOSITE OUT is a standard VOR/Localizer Composite output signal which may be used
to drive the Left/Right, TO/FROM, and Flag indications of certain navigation indicators that contain an
internal converter.
The ILS ENERGIZE output goes low when the VLOC frequency is channeled to a localizer channel.
4.8.2

VOR/ILS Indicator Electrical Characteristics

4.8.2.1
Superflags
VOR/LOC SUPERFLAG
GLIDESLOPE SUPERFLAG
The output supplies not less than 500 mA on a 28 volt system and 250 mA on a 14 volt system with the
output voltage not less than (AIRCRAFT POWER - 3 VDC) when the flag is to be OUT OF VIEW. The
output voltage with respect to ground is less than 3 VDC when the flag is to be IN VIEW.
4.8.2.2
Deviation
VOR/LOC +LEFT
VOR/LOC +RIGHT (VOR/LOC COMMON)
GLIDESLOPE +UP
GLIDESLOPE +DOWN/-FLAG (GLIDESLOPE COMMON)
The deviation outputs are each capable of driving up to three 1000
10% with respect to 2.5V Common for full-scale deflection. The drive circuit provides for more than
full-scale deflection with a maximum course deviation output voltage of ±300 mVDC 10%.
4.8.2.3
TO/FROM
VOR/LOC +TO
VOR/LOC +FROM (VOR/LOC COMMON)
The output is capable of driving up to three 200
±75 mVDC. When indicating FROM, output is -225 ±75 mVDC. When invalid information is present
(Flag IN VIEW) the TO/FROM output is 0 ±10 mVDC.
Page 4-18
Rev. G
NOTE
Pin Name
Pin Name
Pin Name
meter loads. When indicating TO, the output is +225
Connector
Pin
P4006
15
P4006
38
Connector
Pin
P4006
5
P4006
6
P4006
32
P4006
31
meter loads with 150 mVDC
Connector
Pin
P4006
1
P4006
2
GNS 400W Series Installation Manual
I/O
Out
Out
I/O
Out
Out
Out
Out
I/O
Out
Out
190-00356-08

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gns 430 awGnc 420awGnc 420wGns 430w

Table of Contents