Ras-18Gfp-Es2 / Ras-18Ga-Es2 - Toshiba RAS-18GFHP-ES2 Service Manual

Under ceiling console type
Table of Contents

Advertisement

5-2. RAS-18GFP-ES2 / RAS-18GA-ES2

0.39m
(Connecting pipe)
∅12.70 mm
0.39m
(Flexible pipe)
∅12.70 mm
O.D.:12.70 mm
Packed valve
(∅12.70)
Compressor
PA225X2CS-4KU1
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Multi blade fan
P
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
1.1
1.2
0.6
T
Refrigerant
R-410A 1.26 Kg
Mark (
Surface temp. of heat
exchanger interchanging
pipe T (°C)
10.0
13.0
2.0
– 16 –
FILE NO. SVM-06021
0.49m
(Connecting pipe)
∅6.35 mm
O.D.:6.35 mm
Packed valve
(∅6.35)
Capillary tube
∅1.7x400S
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(°C)
(indoor)
Indoor
Outdoor
High
27/19
High
32/23
Low
21/15
35/24
43/26
21/15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents