Advertisement

4-3. Outdoor Unit (RAS-18GAH-ES2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcomputer
10
Varistor (R73, R74)
11
Fuse (F01)

4-4. Indoor Unit (RAS-24GFP-ES2, RAS-18GFP-ES2)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Micro Power Module (M01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C63)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R319)
12
Louver motor
13
Relay : (RY04)
Type
Output (Rated) 1500W, 2poles, 1 phase, 220 − 240V, 50Hz
PA225X2CS-4KU1 Winding resistance (Ω)
(at 20°C)
Output (Rated) 42W, 4poles, 1 phase, 220 – 240V, 50Hz
FG-240-42A-1
Winding resistance (Ω)
(at 20°C)
451305L
AC 450V, 3.0 µF
RS44B506U0218S AC 440V, 50µF
VHV (STF)
AC 220 − 240V
TE / TD
10kΩ at 25°C / 50kΩ at 25°C
CLK-26J
220 − 240V, 50Hz
TT-05
220 − 240V
TMP47C840N
15G471K
470V
T6.3A, 250V
TSCR
Type
AFS-220-31-4A
———
µRM1260V
TMP87CM40AN
———
LC*SS11V-06270
D3SBA60
KMH400VSSN47M22S
BET6.3A
TND15G561K
RF-2TK5R6
35BYJ46
G5NB-1A
- 13 -
FILE NO. SVM-06021
Specifications
Red-Black
1.54
Red-Black
128
Specifications
AC 200 − 240V, 31W
10 kΩ at 25°C
DC 390 V, Secondary DC 12 V
10 kΩ at 25°C
27mH, 600mA
4 A, 600 V
4.7µF, 400 V
T6.3 A, 250 V
560 V
5.6Ω , 2 W
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
Coil DC 12V, 16.7mA, Contact AC 250V, 1A
White-Black
2.48
White-Black
126

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents