4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-24GFHP-ES2, RAS-18GFHP-ES2)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
DC-DC transformer (T01)
4
Microcomputer
Heat exchanger sensor
5
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C02)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R01)
12
Louver motor

4-2. Outdoor Unit (RAS-24GAH-ES2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcontroller
10
Varistor (R73, R74)
11
Fuse (F01)
Type
AFP-220-50-4A
———
SWT-47
TMP87CM40AN
———
SS11V-R07190
D3SBA60
EKMH401VSN470MP20S 47µF, 400V
TSCR
15G561K
RF-2TK5R6
MP35EA12
Type
Output (Rated) 2200W, 2poles, 1 phase, 220 − 240V, 50Hz
PA290X3CS-4MU1 Winding resistance (Ω)
(at 20°C)
Output (Rated) 42W, 4poles, 1 phase, 220 – 240V, 50Hz
FG-240-42A-1
Winding resistance (Ω)
(at 20°C)
451305L
AC 450V, 3.0µF
RS44B506U0218S AC 440V, 50µF
VHV (STF)
AC 220 ~ 240V
TE / TD
10kΩ at 25°C / 50kΩ at 25°C
CLK-35J
220 ~ 240V, 50Hz
TT-05
220 ~ 240V
TMP47C840N
15G471K
470V
TSCR
T6.3A, 250V
- 12 -
FILE NO. SVM-06021

Specifications

Output (Rated) 50W, 220-240V
10kΩ at 25°C
DC 390V, Secondary DC 12V, 7V
10kΩ at 25°C
19mH, AC0.7A
4A, 600V
T6.3A, 250V
560V
5.6Ω, 2W
Output (Rated) 2W, 6poles, 4phase,
DC 12V
Specifications
Red-Black
1.13
Red-Black
128
White-Black
2.10
White-Black
126