Outdoor Unit (Ras-24Ga-Es2); Outdoor Unit (Ras-18Ga-Es2) - Toshiba RAS-18GFHP-ES2 Service Manual

Under ceiling console type
Table of Contents

Advertisement

4-5. Outdoor Unit (RAS-24GA-ES2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor

4-6. Outdoor Unit (RAS-18GA-ES2)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
Output (Rated) 2200W, 2poles, 1 phase, 220 − 240V, 50Hz
PA290X3CS-4MU1 Winding resistance (Ω )
(at 20°C)
Output (Rated) 42W, 4poles, 1 phase, 220 − 240V, 50Hz
FG-240-42A
Winding resistance (Ω)
(at 20° C)
451305L
AC 450V, 3.0µ F
RS44B506U0218S AC 440V, 50µ F
220 − 240V, 50Hz
CLK-35J
Type
Output (Rated) 1500W, 2poles, 1 phase, 220 − 240V, 50Hz
PA225X2CS-4KU1 Winding resistance (Ω)
(at 20°C )
Output (Rated) 42W, 6poles, 1 phase, 220 − 240V, 50Hz
WLF-240-42A-1
Winding resistance (Ω)
(at 20°C)
451205L
AC 450V, 2.0µF
RS44B506U0218S
AC 440V, 50µF
220 − 240V, 50Hz
CLK-26J
- 14 -
FILE NO. SVM-06021
Specifications
Red-Black
White-Black
1.13
Red-Black
White-Black
128
Specifications
Red-Black
White-Black
1.54
Red-Black
188
2.10
126
2.48
White-Black
289

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents