4-10-8. Replacing the BW Motor

As the dust-proof area in the scanner is opened by the following procedure, do not replace the following parts in a dusty
room.
Refer to
Section 6-13
for the part number of the replacement part.
<Removing>
(1) Remove Chute unit (ADF paper chute), Stacker unit, PCB unit, Rear cover, Upper cover and Guide A ASSY by
referring to Sections from
(2) Remove the Dust cover by referring to
(3) Remove two motor cables that run on the backside of the
scanner from a hole of chassis and all hooks.
(4) Remove two screws that are fixing the BW motor. Slide
the motor inside and tilt it to remove the motor from the
Upper unit.
Reference: BW motor includes the cable.
<Mounting>
Follow the removing procedure in reverse.
(1) Fix the motor so that the connector of the cable shall be
located in lower side.
(2) When routing the motor cable on backside of the scanner,
insert thinner cable first to avoid cables come out the
hooks.
05
Nov. 20, 2008
K.Okada
T.Anzai
04
July 7, 2008
K.Okada
T.Anzai
03
Feb.23, 2007
K.Okada
K.Okada
Rev
DATE
DESIG.
CHECK
Aug.19, 2005
DESIG
K.Okada
CHECK
N
4-7-1
to 4-7-6.
Section
4-10-3.
I.Fujioka
Refer to Revision Record on page 2.
I.Fujioka
Refer to Revision Record on page 2.
T.Anzai
Refer to Revision Record on page 2.
APPR.
DESCRIPTION
K.Okada
T.Anzai
APPR.
Cables for motor
Screws for BW Motor
The connector of
the cable shall be
lower side.
BW Motor
Cables for motors
TITLE
fi-5530C/fi-5530C2
MAINTENANCE MANUAL
DRAW.
P1PA03334-B30X/6
No.
PFU LIMITED
Section 4-10-8
Hole of chassis
Hole of chassis
IMAGE SCANNER
CUST.
PAGE
91
138
/

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fi-5530c2

Table of Contents