The furnace-mounted filter rack includes a rack mounted on
the top of the furnace. Two filters fit into the rack and rest
against the sides of the return air plenum, forming a "V"
above the furnace. (Figure 11)
The filters should be inspected and cleaned or changed ev-
ery two months or as required. In some installations, the
filters can be inspected and cleaned or changed after dis-
connecting the electrical power and removing the optional
access door in the return air plenum. If the installation does
not have an access door proceed as follows:
1. Disconnect the electrical power.
2. Remove the upper door from the furnace.
3. Remove the left filter first by reaching to the left side of
the blower, pushing the filter up slightly to remove it from
the filter rack. Then carefully pull the filter down past the
left side of the blower housing. Be careful not to dis-
lodge any trapped dirt or debris from the filter. (Figure
10)
4. Remove the right filter by reaching to the left side of the
blower. Lift filter up slightly to remove it from the filter
rack. Move the filter to the left side of the return air ple-
num, and down past the left side of the blower housing.
Be careful not to dislodge any trapped dirt or debris from
the filter. (Figure 10)
a. Some installations will have two throwaway filters. If
dirty, these filters must be thrown away and replaced
with two new similar size throwaway filters.
b. Other installations will have two permanent filters.
Wash, rinse and dry dirty permanent filters. After
cleaning, both sides should be sprayed with a filter
adhesive (available in hardware stores) as instructed
on the adhesive container.
When badly torn or uncleanable, permanent filters
must be replaced with permanent filters of the same
type and size.
6. To reinstall the filters, first MAKE CERTAIN THE AIR-
FLOW DIRECTION ARROW POINTS TOWARDS THE
FURNACE. Then insert the filters from the left side of
the blower. Starting with the right filter, push the filter
into the plenum so that the bottom of the filter rests in
the filter rack and the upper edge rests against the side
of the plenum. Repeat with the left filter. (Figure 11)
7. Replace the blower door, then reconnect the electrical
power.
Ask a participating Amana dealer about Amana's extended service plan. It adds to the
strong warranty with additional parts and labor coverage.

Horizontal Filters (Not Included With Furnace)

For furnaces installed horizontally, filters must be installed
external to the furnace casing. A central return with filters
installed in the duct behind the return grille may be used.
This would simplify filter replacement by merely requiring
the removal of the grille. Clean or replace filters every two
months or sooner as required. Dirty filters are the most com-
mon cause of inadequate heating or cooling performance.

Induced Draft Motor Lubrication

The induced draft motor bearings are permanently lubricated.
No further lubrication is required.

Air Circulating Blower Motor Lubrication

The air circulation blower motor bearings are permanently
lubricated. No further lubrication is required.
IV. For More Information
Most questions can be answered by the local Amana dealer.
Check with dealer first if needing any further information
regarding the operation, maintenance, or service of the fur-
nace.
If you have any matters that are not resolved locally, or for
more information on other heating and cooling products or
kitchen appliances offered by Amana is needed - please call:
CONSUMER INFORMATION LINE
AMANA TOLL FREE
1-800-843-0304 (U.S. only)
(Not a technical assistance line for dealers.)
________________________________________
Outside the U.S., call 1-319-622-5511.
(Not a technical assistance line for dealers.)
Your telephone company will bill you for the call.
Ask your participating Amana dealer about Amana's ex-
tended service plan. It adds to the strong warranty with addi-
tional parts and labor coverage.
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gci*Gui seriesGci series

Table of Contents