Gas Line Installations - Desa (V)GM36 Installation Instructions Manual

36”, 42", 50" wood burning (herringbone ) masonry fireplace with insulation
Table of Contents

Advertisement

OPTIONAL GAS LINE INSTALLATION
Gas line hook up should be done by your supplier or a
qualified service person.
NOTE: Before you proceed, make sure your gas supply is
turned off.
Use only a ½ inch black iron pipe and appropriate fittings.
STEP 1: To install, remove the knockout indentation on the
refractory, (or firebrick), wall located above the refractory
hearth floor. The knockout indentation must be firmly tapped
with any solid object until it is released. Remove fragmented
portions of refractory (see figure 19).
Figure 19
GAS LINE KNOCKOUT
STEP 2: Remove gas line cover plate located on either side of
fireplace and pull out insulation from gas line conduit sleeve.
Save insulation for reuse.
STEP 3: Run a ½ inch black iron gas line into the fireplace
through the rear at gas line conduit sleeve (if using a raised
platform, add height).
fireplace chamber for fitting connection (see figure 20).
NOTE: Secure incoming gas line to wood framing to provide
rigidity for threaded end.
STEP 4: Repack insulation around gas line and into sleeve
opening.
Seal any gaps between gas line and refractory
knockout hole with refractory cement or commercial furnace
cement. Install the gas appliance or cap-off gas line if desired.
Provide sufficient gas line into
Figure 20
GAS LINE INSTALLATION
CAUTION: All gas piping and connections must be tested
for leaks after the installation is completed. After ensuring
that the gas valve is on, apply soap and water solution to
all connections and joints. Bubbles forming show a leak.
Correct all leaks at once.
FLAME FOR LEAK TESTING AND DO NOT
OPERATE ANY
DETECTED. LEAK TESTING SHOULD BE DONE BY
A QUALIFIED SERVICE PERSON.
WARNING: Do not operate an unvented gas log set in
this fireplace with the chimney removed.
If you install a decorative gas appliance (vented gas log), the
decorative gas appliance must comply with the Standard for
Decorative Gas Appliance for Installation in Solid Fuel
burning Fireplaces, ANS Z21.60, Z21.84 or RGA 2-72, and
shall also be installed in accordance with the National Fuel
Gas Code, ANS Z223.1-NFPA 54 latest edition.
WARNING: If the fireplace has been used for wood
burning, the firebox and chimney must be cleaned of soot,
creosote and ashes by a qualified chimney cleaner.
Creosote will ignite if highly heated.
WARNING: When using a decorative vented gas log,
the damper must be removed or permanently locked in the
fully open position and the glass doors must be in the fully
open position.
-
-
11
DO NOT USE AN OPEN
APPLIANCE
IF
A
LEAK
For more information, visit www.desatech.com
IS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vgm42Vgm50hVgm42hVgm50Gm36Gm42 ... Show all

Table of Contents