Desa (V)G36 Owner's Operation And Installation Manual

36" wood burning masonry fireplace smooth face with insulation

Advertisement

36" Wood Burning MaSonry Fireplace
oWner'S operaTion and inSTallaTion Manual
(V)G36 - Smooth Face with Insulation
(V)G36R - Smooth Face with Insulation and Bottom Door Rail
(V)G36H - Smooth Face with Insulation and Herringbone Refractory
(V)G36HR - Smooth Face with Insulation, Bottom Door Rail
and Herringbone Refractory
SAVE THIS BOOK
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep
it with your other important papers.
This fireplace is approved for use as a wood burning
fireplace or for use with a vented gas log approved to
ANS Z21.60, Z21.84 or RGA 2-72 standards or for use
with a vent-free gas log heater approved to ANS Z21.11.2
standard.
This wood burning fireplace complies with UL127-
CAN/ULS-S610-M87 standard as a FACTORY BUILT
APPLIANCE.
FOR CANADA: The authority having jurisdiction (such
as the municipal building department, fire department,
etc.) should be contacted before installation to deter-
mine the need to obtain a permit.
Save this manual for future reference.
For more information, visit www.desatech.com

Advertisement

Table of Contents
loading

Summary of Contents for Desa (V)G36

  • Page 1 36" Wood Burning MaSonry Fireplace oWner’S operaTion and inSTallaTion Manual (V)G36 - Smooth Face with Insulation (V)G36R - Smooth Face with Insulation and Bottom Door Rail (V)G36H - Smooth Face with Insulation and Herringbone Refractory (V)G36HR - Smooth Face with Insulation, Bottom Door Rail and Herringbone Refractory SAVE THIS BOOK This book is valuable.
  • Page 2: Table Of Contents

    Unless you use DESA components, which have been designed and tested for the fireplace system, you may cause a fire hazard. • The DESA warranty will be voided by and DESA disclaims any responsibility for the following actions. a. Modification of the fireplace, components, doors, air inlet system and damper control.
  • Page 3: Specifications

    1" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL " AIR SPACE BACK AND SIDES OUTSIDE AIR GAS LINE KNOCKOUTS 67" 58" 49" 8" 1" 116010-01C SpeciFicaTionS ROUND TOP TERMINATION 0" TO 12" EACH SIDE BOTTOM 12" 30" 36" 45" 21.5" 20" 36"...
  • Page 4: Fireplace Installation

    Fireplace inSTallaTion SELECTING LOCATION To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Figures 1 and 2). 2. Consider a location where the fireplace will not be affected by drafts, air conditioning ducts, windows or doors.
  • Page 5: Hearth Extension

    Fireplace inSTallaTion Continued HEARTH ExTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fire- place.
  • Page 6: Venting Installation

    Before Installing in a Vented Crawl Space) Figure 5 - Outside Air Kit CHIMNEY PIPE The DESA chimney system consists of 12", 18", 24", 36" and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths...
  • Page 7 VenTing inSTallaTion Continued USING ELBOW OFFSETS (30E-12DM) 1. To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 7). OFFSET RISE CHIMNEY LENGTH 12" 18" "...
  • Page 8 VenTing inSTallaTion Continued Screws Figure 9 - Elbow Offset FIRESTOP SPACERS (1100EFS-10DM) Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 10.
  • Page 9: Chase Installations

    VenTing inSTallaTion Continued FLASHING INSTALLATION (V6F-10DM OR V12F-10DM) Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see Figure 13).
  • Page 10: Optional Gas Line Installation

    VenTing inSTallaTion Continued 4" Min. 4" Min. Figure 16 - Multiple Chase Installation 10 FOOT RULE All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the highest point of the roof that is within a horizontal distance of 10 feet (see Figure 17).
  • Page 11: Glass Door Installation

    opTional gaS line inSTallaTion Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak.
  • Page 12: Operation And Maintenance Guidelines

    glaSS door inSTallaTion Continued 5. Remove three screws located at front of fire- box (see Figure 21). 6. Align bottom rail mounting holes with holes at front of firebox and secure with screws removed in step 5. 7. Place ash box in place. Replace center brick. Bottom Door Rail Ash Box...
  • Page 13: Maintenance Guidelines

    Pulling lever down will lock the door. WARNING: Risk of fire! Re- place grate with DESA model 109496-03 grate only. This grate has been designed to keep the operation of your fireplace safe and efficient.
  • Page 14: Technical Service

    If so, contact DESA’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready. You can also visit DESA’s technical services web site at www.desatech.com. replaceMenT parTS HERRINGBONE BRICK LINER...
  • Page 15: Accessories

    acceSSorieS BI-FOLD GLASS DOOR BDG36 - 36" Black Finish BDG36B - 36" Brushed Brass Finish BDG36P - 36" Platinum Finish BDG36PB - 36" Polished Brass Finish DOUBLE WALL PIPE 18-12DM, 24-12DM, 36-12DM, 48-12DM, 12-12HT, 18-12HT, 24-12HT, 36-12HT and 48-12HT 30° OFFSET AND RETURN 30E-12DM and 30E-12HT OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION - AK4F...
  • Page 16 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com 116010 01 NOT A UPC 116010-01 Rev. C 1/05...

This manual is also suitable for: