36" Wood Burning Masonry Fireplace
oWner's operaTion and insTallaTion Manual
ICC-ES #ESR-2542
(V)G36 - Smooth Face with Insulation
(V)G36R - Smooth Face with Insulation and Bottom Door Rail
(V)G36H - Smooth Face with Insulation and Herringbone Refractory
(V)G36HR - Smooth Face with Insulation, Bottom Door Rail
and Herringbone Refractory
SAVE THIS BOOK
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep
it with your other important papers.
This fireplace is approved for use as a wood burning
fireplace or for use with a vented gas log approved to
ANS Z21.60, Z21.84 or RGA 2-72 standards or for use
with a vent-free gas log heater approved to ANS Z21.11.2
standard.
This wood burning fireplace complies with UL127-
CAN/ULS-S610-M87 standard as a FACTORY BUILT
APPLIANCE.
FOR CANADA: The authority having jurisdiction (such
as the municipal building department, fire department,
etc.) should be contacted before installation to deter-
mine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.desatech.com

Advertisement

Table of Contents
loading

Summary of Contents for Desa V)G36HR

  • Page 1 36" Wood Burning Masonry Fireplace oWner’s operaTion and insTallaTion Manual ICC-ES #ESR-2542 (V)G36 - Smooth Face with Insulation (V)G36R - Smooth Face with Insulation and Bottom Door Rail (V)G36H - Smooth Face with Insulation and Herringbone Refractory (V)G36HR - Smooth Face with Insulation, Bottom Door Rail and Herringbone Refractory SAVE THIS BOOK This book is valuable.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualified installer or local distributor. TaBle oF conTenTs Safety ..............2 Glass Door Installation ........
  • Page 3: Specifications

    saFeTy Continued WARNING: Always leave glass doors fully opened or fully closed when operating fireplace. speciFicaTions ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 1" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD " AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 12"...
  • Page 4: Fireplace Installation

    Fireplace insTallaTion SELECTING LOCATION FRAMING To determine the safest and most efficient 1. Frame opening for fireplace using dimen- location for the fireplace, you must take into sions shown in Figures 1 and 2. consideration the following guidelines: 2. If fireplace is to be installed directly on 1.
  • Page 5: Fireplace Installation

    Fireplace insTallaTion Continued HEARTH ExTENSION MANTELS A hearth extension projecting a minimum of A mantel may be installed if desired (see Figure 20" in front of and a minimum of 12" beyond 4). Woodwork such as wood trims, mantels or each side of fireplace opening is required to any other combustible material projecting from protect combustible floor construction in front...
  • Page 6: Venting Installation

    VenTing insTallaTion OPTIONAL OUTSIDE AIR KIT WARNING: The opening in (MODEL AK4/AK4F) collar around chimney at top of Installation of an outside air kit should be fireplace must not be obstructed. performed during rough framing of fireplace due to the nature of it's location. Outside com- Never use blown insulation to fill bustion air is accessed through a vented crawl chimney enclosure.
  • Page 7: Venting Installation

    VenTing insTallaTion Continued Continue to assemble chimney sections as USING ELBOW OFFSETS (30E-12DM) outlined above, making sure that both inner 1. To achieve desired offset, you may install and outer pipe sections are locked together. combinations of 12", 18", 24", 36" and 48" When installing double wall snap-lock chim- length of double wall pipe (see offset chart ney together, it is important to assure the joint...
  • Page 8 VenTing insTallaTion Continued Return Return Elbow Elbow Return Offset Offset Elbow Elbow Elbow 6' Max. 6' Max. Ceiling Support Pipe Return 12S-12DM 6' Max. Return Elbow Elbow 6' Max. Offset Offset Elbow 6' Max. Elbow 6' Max. Offset Elbow Figure 9 - Typical Offset Terminations Screws or Staples FIRESTOP SPACERS (1100EFS-10DM) Firestop...
  • Page 9 VenTing insTallaTion Continued 5. Add next sections of pipe until the end pen- Installing Flashing on a Metal Roof etrates the roof line. Check to see that the When installing flashing on a metal roof, it proper clearances are maintained. Extend is required that putty tape be used between chimney by adding sections of double wall flashing and roof.
  • Page 10: Optional Gas Line Installation

    VenTing insTallaTion Continued 10 FOOT RULE CAUTION: Do not seal open- All flue gas outlet chimney terminations must ings on the rooftop flashing. Fol- extend a minimum of 3 feet in height above the low the installation instructions highest point where it passes through the roof and must be at least 2 feet above the high- provided with the termination est point of the roof that is within a horizontal...
  • Page 11 opTional gas line insTallaTion Continued 2. Remove gas line cover plate located on either side of fireplace and pull out insu- WARNING: Do not oper- lation from gas line conduit sleeve. Save ate an unvented gas log set in insulation for reuse. Replace screws. this fireplace with the chimney 3.
  • Page 12: Glass Door Installation

    glass door insTallaTion INSTALLING GLASS DOORS IMPORTANT: Install glass door Spring clips have been installed but some frame before installing glass adjustments may be needed. If doors do not door. close properly or do not appear straight, see Door Adjustment. INSTALLING DOOR FRAMES 1.
  • Page 13: Operation And Maintenance Guidelines

    operaTion and MainTenance guidelines GLASS DOORS Cleaning Glass Clean glass with any commercial glass Glass doors are optional with this fireplace. cleaner or soap and water. Do not use any When fireplace is in operation, doors must be abrasive material to clean glass. Do not clean fully opened or fully closed position only or a glass with any cool water if glass is still hot fire hazard may be created (see Figure 24).
  • Page 14: Replacement Parts

    operaTion and MainTenance guidelines Continued Open Position Damper Closed Position Weight To Close Damper Figure 26 - Outside Air Kit Lever Damper Weight To Open Damper Figure 25 - Operating Damper Handle replaceMenT parTs HERRINGBONE BRICK LINER STANDARD BRICK LINER Bottom Front Brick Refractory Bottom Front Brick Refractory 116092-01 - VG36H Models...
  • Page 15: Technical Service

    replaceMenT parTs Technical serVice Continued You may have further questions about installa- tion, operation, or troubleshooting. If so, con- tact DESA Heating, LLC at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready. You can also visit DESA Heating, LLC’s web site at www.desatech.com.
  • Page 16 accessories Continued FIRESTOP SPACER - 1100EFS-10DM SQUARE CHASE-TOP TERMINATION - STL-12D ROOF FLASHING V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch ROUND TOP TERMINATIONS RLT-12D AND RLT-12HT DESA Heating, LLC 2701 Industrial Drive Bowling Green, KY 42101 www.desatech.com 116010-01 116010 01...