Check FLiRS / Always Listening mode in ZTS-110

Procedure / Description
During normal operation, press and keep
holding the keys on "Fan" + "Mode" + "Prog"
for 3 seconds.
(The unit will resume to normal operation
after released all keys.)
- If the LCD displays "bt", the unit is
detected to be FLiRS mode if it will be
included into Z-Wave network;
- If the LCD displays "AC", the unit is
detected to be Always Listening mode if it
will be included into Z-Wave network;
- If the LCD displays "bt" + "RF icon", the
unit is in FLiRS mode and is included into
Z-Wave network;
- If the LCD displays "AC" + "RF icon", the
unit is in Always Listening mode and is
included into Z-Wave network.
Note:
After Z-Wave inclusion process, if you reset ZTS-110 to default while both 24Vac
and batteries are applied, ZTS-110 will take 24Vac as primary power source and
self-configure to Always Listening Mode. If you are using battery as back up, and
the AC power is down, the battery will drain very fast, battery will only survive 3-5
days.
Z-Wave Add (Include) / Delete (Exclude) into/from Z-Wave network
Add (Include) ZTS-110 to Gateway / Controller Z-Wave
network
Symbol
Inclusion and Exclusion Mode Key Description
Add (Include) / Delete (Exclude)