Filter Counter

Step
Procedure / Description
Press and hold "Fan" key for 2 seconds to
check the filter counter.
1
The "usage hours" will be shown on screen.
Press and hold "Prog" key for 2 seconds to
2
reset the filter counter after replace a new
filter.
Press and hold "Mode" key to set the alert
time for the filter usage. "Target" icon will be
shown on screen and flashing.
Press "UP" or "Down" to set the alert time.
(Range from 500 to 4000 Hours Step size
3
is 100hrs)
Press "Prog" key to confirm the setting and
go back to filter counter page.
Press "Home" key once to go back to the
Home page.
FILTER icon will be shown on the screen at
Home page when the usage hours were
4
reached to set time.

Short Cycle Start Up Protection

To protect the compressor / Heat pump, those outputs forced off until 3minutes
count down finished. Those outputs can be activated according to the room
temperature after 3 minutes.