Arada BK545 Installation Manual

Arada BK545 Installation Manual

Dry stove
Hide thumbs Also See for BK545:

Advertisement

Dry Stove Installation Guide
BK545
November 2012
EN 13240:2001+
Rev02
Amd. A2:2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BK545 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Arada BK545

  • Page 1 Dry Stove Installation Guide BK545 November 2012 EN 13240:2001+ Rev02 Amd. A2:2004...
  • Page 2: General Precautions

    Please read carefully through this installation guide before proceeding with installation of the stove. Should you have any questions about our stoves that are not covered in this manual, please contact the Arada retailer in your area, or call our technical support department on 0844 847 5107. WARNING It is a legal requirement that the installation of all new or replacement, wood or solid fuel heating appliances must obtain building control approval from your local authority.
  • Page 3: Combustible Materials

    The fitting of an extractor fan to either of these combustible materials. rooms is not permitted. Certain stoves manufactured by Arada are If the appliance is fitted with a draught suitable for installation on a non-combustible stabiliser or if one is fitted to the flue pipe or 12mm hearth such as glass.
  • Page 4: Installation

    Repeat for the other rear leg. consumption. FIREBOX LINER PANELS SEALING THE BACK AND BASE OF Most Arada stoves use firebox liner panels to the INSET STOVES TO A FIRE sides and back. Some Villager wood burners also SURROUND have firebox liners in the base of the stove. For...
  • Page 5: Flues And Chimneys

    A chimney may comply with regulations but could sweeping of the flue ways other than through still be subject to down draught and the appliance (e.g. wherever possible a soot Arada Installation Manual...
  • Page 6: Final Checklist

    This must be between 1m to 3m of the appliance, and approximately 150mm below the ceiling level.  A fireguard conforming to BS 8423:2002 should be used in the presence of children and old or infirm people. Arada Installation Manual...
  • Page 7 INSTALLATION Arada Installation Manual...
  • Page 8 Telephone: +44 (0)1297 35700 Technical Helpline: +44 (0)8448 475107 Please Note: Arada has a policy of continuous product development and therefore we reserve the right to amend the specification without prior notice. Due to printing cycles, items or options may be described before they are generally available or after they have ceased, so please check with your retailer or dealer.