Page 1
DEFRA Stove Installation and User Guide For stoves ranges: Aarrow DEFRA Signature DEFRA Ecoburn DEFRA Solution DEFRA PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK575 February 2013 EN 13240:2001+ Amd. A2:2004...
Page 2
Do not use aerosol sprays or any other flammable materials near the appliance when in use. Arada Ltd will not be responsible for any consequential or incidental loss or injury however caused. Arada has a policy of continuous product development and therefore we reserve the right to amend the specification without prior notice.
‘HETAS Guide’ which can hearth should be free of combustible materials. be found on HETAS’ website. Certain stoves manufactured by Arada are The positioning of any air vent must be so that suitable for installation on a non-combustible it cannot be liable to blockage or obstruction.
FIREBOX LINER PANELS Note : The flue pipe must be fitted inside the outlet Arada DEFRA stove uses firebox liner panels at spigot. Failure to do so could result in the spillage both sides of the stove. The throat plate is not...
INSTALLATION INSTRUCTIONS All images below are cut-away for clarity FLUES AND CHIMNEYS Insert throat plate assembly into the fire The flue draw is critical on any installation and box and manoeuvre so that the throat should be checked to ensure that it matches plate drops into the landing plate cut- what is specified.
INSTALLATION INSTRUCTIONS the appliance and up the chimney. If this is the in good operating condition. case we recommend the fitting of a draught Check the existing flue is in good condition with stabiliser in preference to a flue damper, in the suitable access for collection and removal of interest of safety and efficiency.
WARNING : Never burn plastics, household waste cold). or liquid fuels in your stove Never leave the appliance unattended for an Please contact Arada Ltd for further details and extended length of time with the door(s) advice on the use of other fuels. open.
USER GUIDE embers the “Ignition Sequence” is complete Important reminders for the user. and re-fuelling for normal use can commence. 1. Take care to insure against blocking or The purpose of these ignition instructions obstructing the permanent air ventilator fitted (lighting from cold) is to ensure that both the to supply combustion air for the appliance.
USER GUIDE over firing. WARNING : Properly installed, with a suitable flue or chimney, operated and maintained correctly, If the chimney connector or casing glows red this appliance will not emit fumes into the the appliance is being over-fired which may dwelling.
USER GUIDE Air Controls Multi Purpose Operating Tool Our DEFRA stoves have one air inlet Your stove is supplied with a multi purpose control for easy operation. operating tool, used for adjusting the air inlet controls and the removal of the ash pan The air inlet provides air through the base of the stove, via the control slider located under the base of the door.
Page 11
USER GUIDE Images of a Generic Stove Wood burning air control position Solid fuel burning air control position Fully Closed Fully Closed Fully Open Fully Open DEFRA Stove Installation and User Guide...
Need help?
Do you have a question about the Aarrow DEFRA and is the answer not in the manual?
Questions and answers