Robertshaw RS4110 Installation Manual

Robertshaw RS4110 Installation Manual

Rs4000 series rs5000 series rs6000 series
Hide thumbs Also See for RS4110:

Advertisement

Available languages

Available languages

INSTALLATION MANUAL

RS4000 Series

QUICK START

4110
RS
5110
RS
6 110
RS
RS5000 Series
STEP 1 Pull backplate straight out
to remove
STEP 2 Install backplate on the wall
and wire
STEP 3 Push front onto backplate
STEP 4 Remove tape on cover
STEP 5 Rotate cover up and remove
battery tray
STEP 6 Place batteries in tray and
place in thermostat
1
4220
RS
RS
5220
RS
6 220
RS
RS
352-00060-001 Rev B
RS6000 Series
4320
20
3
6

Advertisement

Table of Contents
loading

Summary of Contents for Robertshaw RS4110

  • Page 1: Installation Manual

    4110 4220 4320 5110 5220 6 110 6 220 352-00060-001 Rev B INSTALLATION MANUAL RS4000 Series RS5000 Series RS6000 Series QUICK START STEP 1 Pull backplate straight out to remove STEP 2 Install backplate on the wall and wire STEP 3 Push front onto backplate STEP 4 Remove tape on cover STEP 5 Rotate cover up and remove battery tray...
  • Page 2 Thank you for purchasing a Robertshaw ® thermostat. This manual will describe how to install and test the Robertshaw single stage thermostats RS4110, RS5110, RS6110, two stage RS4220, RS5220, RS6220, and three stage* RS4320, RS6320 thermostats. For complete operation instructions, refer to the Robertshaw User Manual.
  • Page 3: Replacing Existing Thermostat

    IMPORTANT SAFETY INFORMATION WARNING: • Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat. • Read all the information in this manual before installing this thermostat. • This is a 24V AC low-voltage thermostat. Do not install on voltages higher than 30V AC.
  • Page 4: Maintaining The Batteries

    Installing the Robertshaw Thermostat Base NOTE: For new installations, mount the thermostat on an inside wall, five feet above the floor. Do not install behind a door, in a corner, near air vents, in direct sunlight, or near any heat or steam generating fixtures.
  • Page 5: Connecting The Wires

    System Switch Selection The body of the thermostat has two switches on the backside. They are accessible by removing the backplate from the body. The installer should set these to match the system. If the thermostat is controlling a heat pump system, set the first switch to Heat Pump.
  • Page 6: Terminal Function

    Terminal Function One Stage Models RS4110, RS5110 and RS6110 EQUIPMENT TO TERMINAL DESCRIPTION CONNECT 24V AC For input of 24V AC common side of transformer. Common Connect to 24V AC common side of the trans- Connection former for line power and nightlight feature.
  • Page 7: Wiring Diagrams

    Transformer 24 Vac 120 Vac Remove jumper if RH/R separate cooling Relay transformer is Reversing present. Valve Not used Compressor for RS4110, Compressor Fault Output RS5110 and Contactor (24VAC) RS6110 Second Not used Stage Cool for RS4110, Second RS5110 and...
  • Page 8 Non-Heat Pump With Battery Backup Transformer 24 Vac 120 Vac Remove jumper if separate cooling RH/R Relay transformer is present. Not used for RS4110, Compressor RS5110 and Contactor RS6110 First Stage Heat Second Not used Stage Cool for RS4110, Second...
  • Page 9: Applying Power

    Applying Power Before applying power, fill in the chart in the Pop-Up Wizard section of this manual. When 24V AC power or battery power is first applied to the thermostat, the display will show the model number followed by the Pop-Up Wizard. The thermostat will start normal operation following the Pop-Up Wizard.
  • Page 10 Pop-Up Wizard The Wizard routine will display factory default settings. Each setting will display for ten seconds. Use the buttons to change the setting. Settings that are not changed will operate with the values that are displayed. To fast forward through the Wizard, press Edit Schedule. The Wizard can be exited by pressing Start/Stop Schedule.
  • Page 11 Default EnergyStar™ Settings for RS5000 and RS6000 The RS5000 and RS6000 series are programmable thermostats and are preprogrammed with a schedule that is recommended by EnergyStar™. The schedule is designed to lower energy costs year-round. EnergyStar™ Temperature Settings Winter (Heating) Summer (Cooling) Morning (6:00 am) 70 °F (21 °C)
  • Page 12 Press to step through the following: Installation Tests for Single Stage Models Conventional (Non-HP) Heat Pump (HP) Demand Terminal Display Terminal Display First Stage Heat W1 + G* Y1 + G First Stage Cool Y1 + G Y1 + G + O * G, will be off (not displayed) for Non-HP with Gas.
  • Page 13: Setting The Mode

    Setting the Mode Press the button to cycle through the available modes. Heat Cool Emergency Heat (Multi-Stage Heat Pump units) Auto changeover (if enabled) Setting Mode to Emergency Heat The multi-stage thermostats have have an emergency heat capability for heat pump systems. An E will be displayed with the heat symbol .
  • Page 14: Thermostat Specifications

    To unlock the buttons: 1. Push and hold the buttons for 5 seconds until the request for password is displayed. 2. Enter the digits for the password by pressing the buttons. Press the to move to the next digit. Press move back.
  • Page 15: Troubleshooting

    Troubleshooting Problem Action Thermostat does not turn on Check wiring (see Wiring Diagrams section). system. Increase temperature differential System turns on too often. (see Pop-Up Wizard section). Move fan option switch to either System fan does not operate gas or electric, to match system properly.
  • Page 16: Five Year Limited Warranty

    Five Year Limited Warranty Invensys Controls warrants to the original contractor installer, or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase. This...
  • Page 17 4110 4220 4320 5110 5220 6 110 6 220 352-00060-001 Rev B INSTALLATION MANUAL RS4000 Serie RS5000 Serie RS6000 Serie COMIENZO RÁPIDO PASO 1 Para retirar la placa posterior tire directamente hacia afuera. PASO 2 Instale la placa posterior sobre la pared y realice las conexiones.
  • Page 18 . Este manual contiene indicaciones para instalar y probar los termostatos Robertshaw de una sola etapa RS4110, RS5110, RS6110, de dos etapas RS4220, RS5220, RS6220, y de tres etapas* RS4320, RS6320. Para ver las instrucciones completas consulte el Manual del Usuario Robertshaw.
  • Page 19 ADVERTENCIAS IMPORTANTES SOBRE SEGURIDAD: • Interrumpa siempre el suministro de electricidad desde la llave principal o desde el panel del disyuntor antes de instalar, retirar, limpiar o reparar el termostato. • Lea toda la información que aparece en este manual antes de instalar el termostato.
  • Page 20 Instalación de la base del termostato Robertshaw NOTA: En instalaciones nuevas, coloque el termostato en una pared interior, cinco pies por encima del piso. No instale detrás de puertas, en rincones, cerca de corrientes de aire, a la luz directa del sol o cerca de dispositivos que generen calor o vapor.
  • Page 21: Mantenimiento De Las Pilas

    Mantenimiento de las pilas Cuando las pilas están bajas, el termostato empieza a funcionar en modo baja energía. El modo pila baja tiene dos niveles. • NIVEL 1: Aparece en el visor el ícono de pila baja. • NIVEL 2: Titila intermitentemente el ícono de pila baja que indica que NO FUNCIONARÁ...
  • Page 22 Función del Terminal Modelos de una etapa RS4110, RS5110 y RS6110 EQUIPO AL QUE SE TERMINAL DESCRIPCIÓN CONECTA Para entrada de lado común del transformador de 24V CA. Para alimentar desde la línea de Conexión común distribución de energía eléctrica y tener la 24VCA característica de luz nocturna conecte al lado...
  • Page 23: Diagrama De Conexiones

    Retire el puente si hay un Relé del RH/R transformador separado ventilador para refrigeración Válvula inversora No se usa en los Salida falla modelos RS4110, Contactor del compresor RS5110 y RS6110 compresor (24VCA) Refrigeración No se usa en los segunda etapa modelos RS4110, Calefacción...
  • Page 24 120 Vac Retire el puente si hay un Relé del RH/R transformador separado ventilador para refrigeración No se usa en los modelos RS4110, Contactor RS5110 y RS6110 del compresor Calefacción de primera etapa Refrigeración de No se usa en los...
  • Page 25 Para conectar a la fuente de energía Antes de conectar a la fuente de energía, complete la tabla de la sección Pop-Up Wizard de este manual. Cuando el termostato se conecta por primera vez con la corriente 24V CA o se colocan las pilas, el visor mostrará el número de modelo y luego aparecerá...
  • Page 26 Pop-Up Wizard La rutina de la pantalla Wizard mostrará los ajustes que vienen de fábrica por defecto. Cada ajuste aparecerá diez segundos. Use las teclas para cambiar los ajustes ingresados. Los ajustes que no se modifiquen funcionarán con los valores mostrados. Para avanzar rápido por la pantalla Wizard, pulse la tecla “Edit Schedule”...
  • Page 27 Ajustes por defecto EnergyStar™ de los mod- elos RS5000 y RS6000 Las series RS5000 y RS6000 son termostatos programables y están preparados de fábrica con un programa que es recomendado por EnergyStar™. El programa está diseñado para ahorrar energía todo el año. Ajustes de temperatura EnergyStar™...
  • Page 28 Si pulsa las teclas repetidamente podrá realizar las pruebas de los modos del sistema. Ver los cuadros siguientes. El visor mostrará los íconos animados correspondientes. Pulse para recorrer lo siguiente: Pruebas de Instalación para Modelos de Una sola Etapa Convencional (No-HP) Bomba de calor (HP) Demanda Terminal...
  • Page 29 Para ajustar el modo Pulse la tecla para pasar por todos los modos posibles. Off (apagado) Heat (calefacción) Cool (refrigeración) Emergency Heat (Calefacción de emergencia) (Unidades con Bombas de Calor de Etapas Múltiples) Auto changeover (if enabled) (conmutación automática (si están activadas) Para fijar el modo calefacción de emergencia Los termostatos de etapas múltiples tienen una característica de calefacción de emergencia para los sistemas de bomba de calor.
  • Page 30 Todas las teclas de la parte anterior ahora están bloqueadas y permanecerán bloqueadas hasta que se ingresa la contraseña. Si pulsa cualquier tecla aparecerá el ícono Para destrabar las teclas: 1. Pulse y mantenga oprimidas las teclas durante 5 segundos hasta que el sistema le solicite la contraseña. 2.
  • Page 31: Resolución De Problemas

    Cuadro del Modo Operacional: Convencional Bomba de calor Bomba de calor Demanda (Non-HP) (HP) Elec (HP) Gas Primera etapa W1 + G* Y1 + G + B Y1 + G + B de calefacción Y1 + Y2 + G + B Y1 + Y2 + G + B Segunda etapa W1 + W2 + G*...
  • Page 32 GARANTIA LIMITADA DE 5 AÑOS Invensys Controls garantiza al instalador contratista original o al usuario original que cada termostato Robertshaw nuevo no tendrá defectos en componentes ni en construcción con el uso y mantenimiento normal durante un período de cinco (5) años desde la fecha de la compra. Esta garantía y nuestra responsabilidad no se aplican a las pilas ni a los...

This manual is also suitable for:

Rs4220Rs4320Rs5220Rs6110Rs6220Rs6320 ... Show all

Table of Contents