Robertshaw RS5110 User Manual

Robertshaw RS5110 User Manual

Programmable thermostat
Hide thumbs Also See for RS5110:

Advertisement

Available languages

Available languages

Thank you for purchasing a Robertshaw RS5000 programmable
thermostat. This user's manual will guide you through the setup of the
RS5110 single stage and the RS5220 two stage thermostats. The
thermostat should already be mounted and correctly wired. The default
settings will enable the thermostat to operate efficiently. Before making
any changes to the schedule read the section on Default Settings.
Features
• Pop-Up Wizard
• Automatic changeover
• Circulating Fan
• Worry-Free memory retention
• Easy change battery
• Large back lit display
• Filter change reminder
• Low battery indicator
• Fahrenheit and Celsius displays
• EnergyStar™ compliant
• Dual power
• Adjustable 1st stage temperature differential: 0.5 °F to 3.0 °F (0.5 °C
to 1.5 °C)
• Accuracy within ±1 °F
• Universal staging on multi-stage units
• Automatic heating shutdown if temperature exceeds 99 °F (37 °C)
• Keypad security lockout
• 4 events per day for heating and cooling
• 5-2 day scheduling
• User settable Hi and Lo temperature limits
• Vacation setpoint override
USERS MANUAL
RS
RS
1
5110
5220
352-00056-001 Rev B

Advertisement

Table of Contents
loading

Summary of Contents for Robertshaw RS5110

  • Page 1 Thank you for purchasing a Robertshaw RS5000 programmable thermostat. This user’s manual will guide you through the setup of the RS5110 single stage and the RS5220 two stage thermostats. The thermostat should already be mounted and correctly wired. The default settings will enable the thermostat to operate efficiently.
  • Page 2 The Robertshaw 5000 family of thermostats is designed to control gas, electric, oil, heat pump, and millivolt heating and electric cooling systems. The RS5110 is a single stage thermostat while the RS5220 is a two-stage thermostat. The RS5000 thermostats use 5-2 programming. This means the 5...
  • Page 3: Installing Or Changing The Batteries

    Installing or Changing the Batteries To remove the battery compartment gently squeeze the ribbed edges on both sides. The battery compartment will pull down from the thermostat body and will detach. Install two AA batteries following the polarity as shown inside the compartment. Place compartment back into the thermostat.
  • Page 4: Emergency Heat

    Emergency Heat Your system may include Emergency Heat. The RS5110 and RS5220 thermostats have an emergency heat capability for multi stage heat pump systems. To determine if your system is capable of using emergency heat contact your contractor.
  • Page 5: Auto Changeover

    Auto Changeover Auto changeover is the ability of the thermostat to switch automatically between heating settings and cooling settings. This is useful in Spring and Fall when the days are warm and the nights are cool. In heat mode if the room continues to warm beyond a set threshold the thermostat switches to the cool mode and the associated cooling settings.
  • Page 6: Setting Time And Day

    Setting Time and Day To adjust the time and day settings press the SET TIME button. The hour will flash. If a button is not pushed in 10 seconds the thermostat returns to operation. To change the settings: 1. Use the buttons to change the flashing number.
  • Page 7: Changing The User Settings

    After the weekend schedule is complete, the display will show the weekend schedule. Continue the same steps to program the four weekend setting When finished press START/STOP SCHEDULE or wait 30 seconds and the thermostat will return to operation. Changing the User Settings When are pressed at the same time the thermostat will display the current settings in order.
  • Page 8 DIFF = The differential keeps the thermostat from turning on for small changes in temperature. When in Fahrenheit the range is 0.5 to 3.0 Degrees. In Celsius the range is 0.5 to 1.5 Degrees. The differential is factory set at 1.0 °F (0.5 °C). This means that whenever the room temperature is more than 1 °F (0.5 °C) different from the set temperature the system will turn on.
  • Page 9 DEDB = Deadband for auto changeover = the number of degrees that the room temperature can move away from the active setpoint until heating or cooling is called for. The larger the deadband the more the room temperature will vary. This can be from heat to cool or cool to heat.
  • Page 10 CHECK = Timer to remind the home owner to maintain the filter. Default setting is off. The timer runs when the system is on. It can be set at 0 (OFF) or up to 9900 hours. When the time expires CHECK FLTR is displayed.
  • Page 11: Energy Efficient Recovery

    2. Enter the digits for the password by pressing the buttons. Press the to move to the next digit. Press move back. 3. When the correct password is set, wait for 5 seconds to unlock the system. 4. If the wrong password is entered the display will flash ---- for 5 seconds then return to normal.
  • Page 12 Temporary Override When the thermostat is running to a schedule, an override allows the thermostat to function with a single setpoint for a time period. A temporary override is entered as a setpoint for a number of hours. 1. Press to display the flashing setpoint and the number of hours.
  • Page 13: Automatic Shutdown

    Permanent Override – The day, time and “schedule” are not displayed. Vacation Override – Vac and For are displayed. The clock shows days of override. The display alternates days of override with setpoint. Temporary Override – The display alternates hours of override with setpoint.
  • Page 14: Troubleshooting

    Troubleshooting Problem Action Check wiring. Thermostat does not turn on system. (See Wiring Diagrams section.) Increase temperature differential. System turns on too often. (See To Make Changes to the Settings section.) Move fan option switch to either gas or electric, to match system. System fan does not operate properly.
  • Page 15: Five Year Limited Warranty

    Five Year Limited Warranty Invensys Controls warrants to the original contractor installer, or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of Five (5) years from date of purchase. This...
  • Page 16: Manual Del Usuario

    5220 352-00056-001 Rev B MANUAL DEL USUARIO Gracias por comprar un termostato programable Robertshaw Serie RS5000. El manual le ayudará a programar el modelo RS6110 de una sola etapa y el modelo RS6220 de dos etapas. El termostato debe estar instalado y conectado adecuadamente a la red de electricidad.
  • Page 17 La familia de termostatos Robertshaw 5000 está diseñada para controlar sistemas de refrigeración eléctrica y de calefacción de gas, electricidad, petróleo, bombas de calor y minivolt. El modelo RS5110 es un termostato de una sola etapa y el RS5220 es un termostato de dos etapas.
  • Page 18 Para instalar o cambiar las pilas Para retirar el compartimiento de las pilas, apriete suavemente los bordes estriados de ambos lados. El compartimiento de pilas de desprenderá del cuerpo del termostato. Coloque dos pilas AA según la indicación de polaridad que figura en el interior del compartimiento.
  • Page 19 Calefacción de emergencia Su sistema puede incluir la función calefacción de emergencia. Los termostatos RS5110 y RS5220 tienen calefacción de emergencia para los sistemas de bomba de calor con etapas múltiples. Para saber si su sistema tiene esta función, comuníquese con el contratista. Use las teclas para ingresar en el modo EMER.
  • Page 20 Conmutación automática La conmutación automática es la posibilidad que tiene el termostato de cambiar automáticamente del modo calefacción al modo refrigeración y viceversa. Esta función es útil en primavera y otoño cuando los días son cálidos y las noches son frescas. En el modo calefacción, si la habitación se sigue calefaccionando por encima del umbral fijado, el termostato cambia automáticamente al modo refrigeración y los valores programados correspondientes.
  • Page 21 Cómo ajustar la hora y el día Para ajustar la hora y el día, pulse la tecla SET TIME (fijar la hora). La hora titilará en forma intermitente. Si no se pulsa ninguna tecla en 10 segundos, el termostato vuelve a ponerse en funcionamiento. Para cambiar los ajustes: 1.
  • Page 22 NOTA: No pueden ingresare valores deseados de calefacción y refrigeración que se entrecrucen. Es decir, el valor deseado de refrigeración no puede ser inferior al valor deseado de refrigeración. Pulse EDIT SCHEDULE y repita el proceso para los tres puntos de ajuste restantes.
  • Page 23 DIFF = El diferencial evita que el termostato se ponga en funcionamiento ante cambios muy pequeños de temperatura. Si está programado en la escala Fahrenheit, el rango de oscilación es de 0.5 a 3.0 grados. Si está programado en la escala Celsius, el rango de oscilación es de 0.5 a 1.5 grados.
  • Page 24 Conmutación automática activada = Hace que esté disponible el modo conmutación automática. Cuando se lo elije., el termostato puede conmutar automáticamente entre calefacción y refrigeración. Nótese que los puntos de ajuste límites Alto y Bajo no son respetados en el modo conmutación automática. DEDB = Margen de oscilación para conmutación automática = cantidad de grados que la temperatura ambiente puede alejarse del valor deseado hasta que empiece a funcionar el modo calefacción o...
  • Page 25 VAC HEAT = valor deseado de calefacción en vacaciones = es el valor deseado de temperatura para el sistema de calefacción cuando se activa el Modo Sobrecontrol por vacaciones. VAC COOL = valor deseado de refrigeración en vacaciones = es el valor deseado de temperatura para el sistema de refrigeración cuando se activa el Modo Sobrecontrol por vacaciones.
  • Page 26 CAL = Compensación de calibración. Cambia la temperatura exhibida de la temperatura real entre +3 y -3 grados en incrementos de un grado. Aumentar la compensación en +2 significa que el termostato mostrará una temperatura que es 2 grados superior a la temperatura ambiente real.
  • Page 27 La segunda etapa vuelve a ponerse en funcionamiento cuando: • La temperatura ambiente se aleja del valor deseado en un incremento que es igual a la suma de los valores diferenciales de la primera y la segunda etapa. • La primera etapa ha estado funcionando durante el tiempo de retardo especificado, pero no se ha alcanzado aún la demanda de calefacción/refrigeración.
  • Page 28 4. Use las teclas para fijar la duración de la cancelación. Después de 5 segundos, el termostato empezará a funcionar en el modo sobrecontrol. El visor mostrará la temperatura ambiente y el valor deseado aparecerá intermitentemente con la cantidad de horas que quedan en el modo sobrecontrol.
  • Page 29: Cierre Automático

    Modo sobrecontrol permanente – No aparecen el día, la hora y el programa. Modo sobrecontrol por vacaciones - Aparece Vac y For. El reloj muestra los días en modo sobrecontrol. El visor alterna los días de modo sobrecontrol con el valor deseado. Modo sobrecontrol temporario –...
  • Page 30: Resolución De Problemas

    Resolución de problemas Problema Solución Verifique el cableado. El termostato no pone en funcionamiento (Ver sección Diagramas de cableado en el sistema. el Manual de Instalación.) Aumente el diferencial de temperatura. El sistema se pone en funcionamiento (Ver sección Para cambiar la muy pronto.
  • Page 31 Garantia Limitada de 5 años Invensys Controls garantiza al instalador contratista original o al usuario original que cada termostato Robertshaw nuevo no tendrá defectos en componentes ni en construcción con el uso y mantenimiento normal durante un período de cinco (5) años desde la fecha de la compra. Esta garantía y nuestra responsabilidad no se aplican a las pilas ni a los...

This manual is also suitable for:

Rs5220

Table of Contents