Specifications
PRIMARY
Mains Input Voltage
Mains protection rating
Maximum power consumption
Power factor cos φ
SECONDARY
Current range I2
Open circuit voltage U20
Welding current l2
InputS1 / current I1
Welding current l2
InputS1 / current I1
Welding current l2
InputS1 / current I1
Selection range (switched steps)
WIRE FEEDER
Supply voltage
Speed
Number of feed rolls
Spool + Spool weight
Dimensions H x W x D
SAFETY
Protection
Insulation class
Standards
Weight
Dimensions H x W x D (fully assembled)
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right
to change, improve or revise the specifications or design of this or any product without prior notice.
Such updates or changes do not entitle the buyer of equipment previously sold or shipped to the
corresponding changes, updates, improvements or replacement of such items.
FABRICATOR 400S III
3ph 400V
50Hz
32A slow blow
16.7 kVA
0.9
55A - 420A
19.3 - 48.0V
Duty
420A
Cycle
30%
16,7kVA/24,2A
Duty
320A
Cycle
60%
12,4kVA/18,0A
Duty
260A
Cycle
100%
9,5kVA/13,6A
2 & 10
24Vac
1-19 m/min
4
max 300 mm + 18 kg
510 x 270 x 700 mm
IP 23S
F
CE / EN 60 974-1 / EN 51099
133kg
1360 x 380 x 870 mm
15
FABRICATOR 500S III
3ph 400V
50Hz
32A slow blow
28.5 kVA
0.9
70A - 520A
20.2 - 59.8V
Duty
530A
Cycle
25%
25.5kVA/43.4A
Duty
400A
Cycle
60%
16.8kVA/24.7A
Duty
320A
Cycle
100%
12.0kVA/17.8A
3 & 10
24Vac
1-25 m/min
4
max 300mm + 18 kg
510 x 270 x 700 mm
IP 23S
F
CE / EN 60 974-1 / EN 51099
161kg
1430 x 440 x 870 mm
Need help?