3.5.

Output

This menu contains adjustments associated with setting up outputs from the unit. The items are
organized in four sub menus, Display Type, Gamma/Color/Crush, Output Config and Output Window
Size. Use the up and down keys to scroll to the required item and press the Menu key.
3.5.1.
Display Type
Settings: LCD/Plasma, Projector, LED
The Display Type setting defaults to LED. In LED mode the Windows Size menu is available which
allows to choose a window of the output mode to fit in a given LED module.
Select Projector if you drive a projector and need the warp function. Set to LCD/Plasma if you do not
need the warp functions to be shown in the menu system. In this mode also the Flicker Filter becomes
available.
3.5.2.
Output Mode
Settings: 640x480, 800x600, 1024x768, 1280x768, 1280x800, 1280x1024, 1400x1050, 1600x1200,
1920x1200, 480i, 576i, 480p, 576p, 1080i, 720p, 1080p
Set up the desired output resolution with output mode. The output mode setting should match the
native resolution of the imaging device to avoid double scaling.
The 3GSDI output does not feature the PC mode resolutions, only 480i/p, 576i/p, 720p and 1080i/p
output modes are supported. Available SDI output modes are indicated by an SDI connector symbol in
the output mode selection list box of the OSD. SDI output modes not supported are indicated with this
symbol crossed out red.
The default output resolution as set by the factory or after a user issued factory reset is 640x480. If
only a SDI capable monitor is connected no image is displayed and consequently the output resolution
cannot by changes through the OSD. Pressing the Menu/Contrast up/Contrast down key combination
will switch the output resolution from 640x480 to 480i which SDI monitors should be capable to display.
If a DVI or VGA monitor has issues to display this 480i mode, by pressing the key combination again
the 640x480 output mode is set-up which all DVI and VGA monitors should be capable to display.
3.5.3.
Location
Settings: Front Tabletop, Front Ceiling, Rear Tabletop, Rear Ceiling
The image can be flipped to accommodate different projection scenarios as well as screens mounted
upside down.
3.5.4.
Frame Rate
Settings: 60 Hz, 50 Hz, 48 Hz, 24 Hz, Auto
In auto mode the output frame rate follows the input frame rate as configured in the Output Config
menu. Signals with 24Hz, 25H, 48Hz, 50Hz (plus margin) input modes get special treatment, modes
with other refresh rates are displayed at 60Hz. 24Hz input modes will be output at 24Hz if the output
resolution is set to either 720p or 1080p and the Frame Rate setting in the Output Config menu
includes 24Hz, otherwise it is displayed at twice the rate if the Frame Rate setting in the Output Config
menu includes 48Hz. Otherwise a 24Hz input mode is displayed at 60Hz. 48Hz input modes will be
output at 48Hz if the Frame Rate setting in the Output Config menu includes 48Hz. Otherwise it is
displayed at 50Hz. A 25Hz input mode is output at twice the frame rate 50Hz. An exception to the
24/25Hz input mode treatment is if the output resolution is set to 480i or 480p. 480i and 480p are
always run at 60Hz output rate. 50Hz input modes are displayed at 50Hz output rate.
©
Calibre UK Limited Issue 2.00
T:+44 1274 394125 F: +44 1274 730960 E: