  • Page 1 HQView-300 Series Operating Instructions Version 2.41...
  • Page 2 HQView-3xx is designed to provide users with a powerful and flexible method of driving large display devices, and multiple screen applications including flexible geometry correction functions. If you have any queries relating to this or any other product supplied by Calibre please visit our web site www.calibreuk.com. For technical support please e-mail techsupport@calibreuk.com...
  • Page 3: Table Of Contents

    User 3.9.2. Names/Profiles 3.9.3. Input Config 3.9.4. Display Mode 3.9.5. Switching Transition 3.9.6. Menu Settings 3.9.7. Network Settings 3.9.8. Factory Defaults © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 4 Introduction 5.2. Updating Firmware ENVIRONMENTAL AND EMC 6.1. Recommended Operating Conditions 6.2. Storage 6.3. CE and FCC Compliance 6.4. PAT Testing © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 5: Safety Warning

    REFER ALL SERVICING AND MAINTENANCE TO QUALIFIED SERVICE PERSONNEL. TO AVOID EXPLOSION, DO NOT OPERATE THIS EQUIPMENT IN AN EXPLOSIVE ATMOSPHERE © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 6: Introduction

    Warp maps created with the PC tool “Warp Generator” can be uploaded into HQView-320. HQView-320 is supported by 3 party PC based auto calibration software creating such warp maps using camera captured information. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 7: Packing List

    1) This manual 2) 3 pin plug IEC mains cable 3) DVI-D output cable 4) CD containing manuals and useful applications © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 8: Hqview-3Xx System Description

    59.94 & 60Hz, 1080p at 24, 25, 30, 50, 59.94 & 60Hz. Signal formats – computer DOS, VGA – WUXGA up to 165MHz pixel clock © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 9: Display Output

    HDCP, the output image will turn black and a message indicating HDCP Signal will come up to indicate this. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 10: Hqview-3Xx Control

    HQVIEW-3XX CONTROL 3.1. Menu Tree HQView-300S Menu Tree Level Level Level Level © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 11 © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 12 © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 13 © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 14 HQView-310 as well as HQView-320 have an additional Warp and Multiple Unit Menu. Level Level Level Level HQView-320 has an additional Discrete Warp Map Item. Level Level Level Level © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 15: Introduction

    With the following multiple key presses further functions can be applied: Keypad unlock: Up/Down Set output and fallback output mode to VGA: Menu/Up Mode reset: Menu/Down Factory reset: Menu/Up/Down © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 16: Main Menu

    Config/Test Pattern Setup. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 17: Output

    A limited video range is only using the following greyscale for video information - 8 Bit System: 0x10 .. 0xEF, 10 Bit System: 0x040 .. 0x03BF, 12 Bit System: 0x100 .. 0xEFF. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 18: Frame Rate

    The status line of the OSD window under Sync Mode indicates if the output signal is locked to the input signal (I/O Locked) or in free run mode (Free Run). © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 19: Native Color Temp

    Settings: -50 to 50 in steps of 1 Control of video hue, applies to all video inputs but not computer input signals or formats. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 20: Rgb Values

    Also, Pin/Barrel distortion of the lens or screen can be adjusted simultaneously. Under the 4-Corner application all corners can be moved and the image is calculated to fit into the given trapezoid. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E: techsupport@calibreuk..com...
  • Page 21: Picture Format

    This menu provided settings to zoom and shrink the image, as well as panning within the image. Pan Tilt Zoom (PTZ) can be switched on or off. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 22 For convenience the PTZ settings can be reset with one button. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 23: Enhancement

    TRNR (Temporal Recursive Noise Reduction) and MNR (Mosquito Noise Reduction) are available for SD input signals only. These filters reduce spatial and temporal noise as well as block artifacts. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 24: System

    For unit control through a web browser or to set up a certain default test pattern please use the input configuration menu. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 25: Display Mode

    HQView-3xx is powered down after such a change, then powered back up, so that it is properly recognised by other devices on the network. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 26: Factory Defaults

    This selection also determines which edges of the picture are provided with soft edge blends. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 27: Blend Width

    Automatic systems control HQView through API calls, in which case the Blend Warping is set automatically and does not need to be touched. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 28: Remote Control Web Server

    TCP/IP address assigned to HQView-3xx can be found in the System/Network Settings menu. 4.3. Discovery Tool Calibre provides a DiscoveryTool.exe Windows application to identify Calibre boxes in the network. http://www.calibreuk.com/downloads/LEDView/DiscoveryTool_V1.0.exe Clicking on the link of the recognized box will open a browser and make a connection to the corresponding box.
  • Page 29: Software Operation

    The alpha map format is B/W 16bit .PNG as e.g. supported by Adobe Paintshop®. Only the most significant 10 bits are used. Also a Calibre proprietary format without compression is supported. This format is intended for uploads in proprietary calibration systems directly controlling the HQView unit. Thus, a .PNG encoder does not have to be implemented on the host side.
  • Page 30 // 2ED608 3F FF FF FF 3F FF FF FF (beginning of last line) // s = CEILING(1920 /3 ) * 4 * 1200 = 3072000 bytes © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...
  • Page 31: Firmware Update

    FIRMWARE UPDATE 5.1. Introduction HQView-3xx has a USB port which allows a PC connection. With the Calibre PC Updater tool new firmware can be installed on HQView-3xx for feature upgrades and bug fixes. http://www.calibreuk.com/downloads/HQView/CalibreUK%20Universal%20Updater%20Installer%20V2. 2.5.msi The latest firmware version for your processor is published on our website at the bottom of this page:- http://www.calibreuk.com/HQViewDownloads.htm...
  • Page 32: Environmental And Emc

    (mains earth). DO NOT CONNECT to the connectors of the rear panel (signal earth). The HQView/LEDView may never work again. © Calibre UK Limited Issue 2.41 November 2013, W: www.calibreuk.com T:+44 1274 394125 F: +44 1274 730960 E:...