Venting - Goodman GSM Installation & Operating Instructions Manual

Sealed combustion condensing furnaces
Table of Contents

Advertisement

When installed as a direct vent furnace and the unit is not using the concentric vent kit (CVK-00)
option, the combustion air is to be terminated in the following manner.
If the optional concentric vent kit (CVK-00) is used follow the instructions provided with this accessory.
The vent / combustion air pipe system should be of the following sizes.
MODEL #
VENT.
GSM(S)
DIA.
060-3
3"
060-3
2"
080-4
3"
080-4
2"
100-4
3"
ANNUAL inspections of the furnace and it's vent / combustion air supply is strongly recommended. It
is the contractor's responsibility to inform the user of this importance.
All venting shall be in accordance with Part 7, Venting of Equipment, of the National Fuel Gas Code,
ANSI Z223.1, or applicable local building and / or air conditioning codes.
PROPER INSTALLATION OF THE VENT / COMBUSTION AIR SYSTEMS IS CRITICAL TO SAFE
OPERATION
OF
INSTRUCTIONS IN THIS SECTION. EACH VENT AND COMBUSTION AIR SUPPLY PIPE MUST
SERVE ONLY ONE APPLIANCE. DO NOT CONNECT TO AN EXISTING VENT OR CHIMNEY.
These furnaces are a condensing type appliance. The products of combustion are recirculated
through a secondary coil. During this process the flue products are brought to a point below dew
point. Thus the moisture present in the flue products condense leaving a liquid by-product. This by-
product must be removed from the furnace and it's collection system.
IO-176
COMBUSTION AIR / VENT PIPE SIZE
COMB.
O ELL
AIR
2"
100'
2"
75'
3"
100'
3"
75'
3"
100'
THIS
APPLIANCE. CAREFULLY
1 ELL
2 ELL
100'
100'
67.5'
100'
100'
67.5'
100'
100'

VENTING

READ
9
3 ELL
100'
60'
52.5'
100'
60'
52.5'
100'
AND
UNDERSTAND
4 ELL
100'
45'
100'
45'
100'
THE