DO NOT install this furnace in a mobile home. This furnace is designed only for installation in
buildings constructed on site and connected to ductwork. When installed in a utility room or closet, the
door should be wide enough to allow the largest part of the furnace to enter, or to permit the
replacement of another appliance, such as a water heater. This furnace is designed to be installed
indoors only. DO NOT install outdoors. This furnace should be installed in such a manner so that it is
protected from water. If any components should become submerged under water, replace those parts
before returning the furnace to operation. DO NOT use as a construction heater. DO NOT install in an
area where freezing can occur without properly protecting the unit and drain system. DO NOT install
in a room designed to be used as a bedroom, bathroom, storage closet, or in any enclosed space
with access only through such room or space. The furnace and it's individual shut-off must be
disconnected from the gas supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5kPa) The furnace must be isolated from the gas supply piping
system by closing it's individual manual shut-off valve during any pressure testing of the gas supply
piping system at pressures equal to or less than 1/2 psig (3.5 kPa).
MINIMUM CLEARANCES TO COMBUSTIB LE SURFACES
Unobstructed front clearance of 24" for servicing is recommended.
VENT - 0"
LEFT SIDE - 1"
ACCESSIBILITY CLEARANCE, WHERE GREATER, SHOULD TAKE PRECEDENCE OVER
MINIMUM FIRE PROTECTION CLEARANCE.
A gas fired furnace for installation in a residential garage must be installed so that the ignition source
and burners are located not less than eighteen inches (18") above the floor and is protected or
located to prevent physical damage by vehicles. A gas furnace must not be installed directly on
carpeting, tile, or other combustible materials other than wood flooring.
COMBUSTIBLE MATERIAL MUST NOT BE PLACED ON OR AGAINST THE FURNACE JACKET.
THE AREA AROUND THE FURNACE MUST BE KEPT CLEAR AND FREE OF ALL
COMBUSTIBLE MATERIAL INCLUDING GASOLINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS. THE USER SHOULD BE CAUTIONED THAT THE FURNACE AREA MUST NOT BE
USED AS A BROOM CLOSET OR FOR ANY OTHER STORAGE PURPOSE.
A SOLID BASE PLATE I S SUPPLIED WITH THIS FURNACE AND MUST BE LEFT IN PLACE
WHEN THE FURNACE IS INSTALLED WITH SIDE RETURN DUCTS. FAILURE TO LEAVE THIS
BASE PLATE INSTALLED COULD CAUSE PRODUCTS OF COMBUSTION, INCLUDING
CARBON MONOXIDE, TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE A
POTENTIALLY HAZARDOUS CONDITION, INCLUDING CARBON MONOXIDE POISONING.
REFER TO THE SECTION ON "CIRCULATING AIR SUPPLY" FOR RETURN DUCT
INSTRUCTIONS.
IO-176

LOCATION

FRONT - 3"
RIGHT SIDE - 1"
REAR - 0"
TOP OF PLENUM - 1"