Hitachi SJ700B SERIES Quick Reference Manual page 53

Inverter
Hide thumbs Also See for SJ700B SERIES:
Table of Contents

Advertisement

Chapter 4 List of Data Settings
Code
Function name
C001
Terminal [1] function (*2)
C002
Terminal [2] function
C003
Terminal [3] function (*2)
C004
Terminal [4] function
C005
Terminal [5] function
C006
Terminal [6] function
C007
Terminal [7] function
C008
Terminal [8] function
C011
Terminal [1] active state
C012
Terminal [2] active state
C013
Terminal [3] active state
C014
Terminal [4] active state
C015
Terminal [5] active state
C016
Terminal [6] active state
C017
Terminal [7] active state
C018
Terminal [8] active state
C019
Terminal [FW] active state
*2
When the emergency stop function is enabled (SW1 = ON), "18" (RS) and "64" (EMR) are forcibly written to parameters "C001" and "C003", respectively. (You cannot arbitrarily write "64" to
"C001".) If the SW1 signal is turned off and then turned on, "no" (no assignment) is set in parameter "C003".
Monitored data or setting
01 (RV: Reverse RUN), 02 (CF1: Multispeed 1 setting), 03 (CF2: Multispeed 2
setting), 04 (CF3: Multispeed 3 setting), 05 (CF4: Multispeed 4 setting), 06 (JG:
Jogging), 07 (DB: external DC braking), 08 (SET: Set 2nd motor data), 09 (2CH:
2-stage acceleration/deceleration), 11 (FRS: free-run stop), 12 (EXT: external
trip), 13 (USP: unattended start protection), 14: (CS: commercial power source
enable), 15 (SFT: software lock), 16 (AT: analog input voltage/current select), 17
(SET3: 3rd motor control), 18 (RS: reset), 20 (STA: starting by 3-wire input), 21
(STP: stopping by 3-wire input), 22 (F/R: forward/reverse switching by 3-wire
input), 23 (PID: PID disable), 24 (PIDC: PID reset), 26 (CAS: control gain
setting), 27 (UP: remote control UP function), 28 (DWN: remote control DOWN
function), 29 (DWN: remote control data clearing), 31 (OPE: forcible operation),
32 (SF1: multispeed bit 1), 33 (SF2: multispeed bit 2), 34 (SF3: multispeed bit 3),
35 (SF4: multispeed bit 4), 36 (SF5: multispeed bit 5), 37 (SF6: multispeed bit 6),
38 (SF7: multispeed bit 7), 39 (OLR: overload restriction selection), 40 (TL:
torque limit enable), 41 (TRQ1: torque limit selection bit 1), 42 (TRQ2: torque
limit selection bit 2), 43 (PPI: P/PI mode selection), 44 (BOK: braking
confirmation), 45 (ORT: orientation), 46 (LAC: LAD cancellation), 47 (PCLR:
clearance of position deviation), 48 (STAT: pulse train position command input
enable), 50 (ADD: trigger for frequency addition [A145]), 51 (F-TM:
forcible-terminal operation), 52 (ATR: permission of torque command input), 53
(KHC: cumulative power clearance), 54 (SON: servo-on), 55 (FOC: forcing), 56
(MI1: general-purpose input 1), 57 (MI2: general-purpose input 2), 58 (MI3:
general-purpose input 3), 59 (MI4: general-purpose input 4), 60 (MI5:
general-purpose input 5), 61 (MI6: general-purpose input 6), 62 (MI7:
general-purpose input 7), 63 (MI8: general-purpose input 8), 65 (AHD: analog
command holding), 66 (CP1: multistage position settings selection 1 ), 67 (CP2:
multistage position settings selection 2), 68 (CP3: multistage position settings
selection 3), 69 (ORL: Zero-return limit function), 70 (ORG: Zero-return trigger
function), 71 (FOT: forward drive stop), 72 (ROT: reverse drive stop), 73 (SPD:
speed / position switching), 74 (PCNT: pulse counter), 75 (PCC: pulse counter
clear), no (NO: no assignment)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
4 - 10
Setting
Change
Default
during
during
operation
operation
(allowed or
(allowed or
_F/_FF
_FUF
not)
not)
18
(*2)
16
06
(*2)
11
09
03
02
01
00
00
00
00
00
00
01
00
00
00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents