Function Mode - Hitachi SJ700B SERIES Quick Reference Manual

Inverter
Hide thumbs Also See for SJ700B SERIES:
Table of Contents

Advertisement

Code
Function name
d022
Life-check monitoring
d023
Program counter
d024
Program number monitoring
d025
User monitor 0
d026
User monitor 1
d027
User monitor 2
d028
Pulse counter
d029
Position setting monitor
d030
Position feedback monitor
d080
Trip Counter
Trip monitoring 1
d081
Trip monitoring 2
d082
Trip monitoring 3
d083
Trip monitoring 4
d084
Trip monitoring 5
d085
Trip monitoring 6
d086
d090
Programming error monitoring
d102
DC voltage monitoring
d103
BRD load factor monitoring
d104
Electronic thermal overload monitoring

4.3 Function Mode

Code
Function name
Output frequency setting
F001
F002
Acceleration (1) time setting
F202
Acceleration (1) time setting, 2nd motor
F302
Acceleration (1) time setting, 3rd motor
F003
Deceleration (1) time setting
F203
Deceleration time setting, 2nd motor
F303
Deceleration time setting, 3rd motor
F004
Keypad Run key routing
Monitored data or setting
2
1
0 to 1024
0000 to 9999
-2147483647 to 2147483647 (upper 4 digits including "-")
-2147483647 to 2147483647 (upper 4 digits including "-")
-2147483647 to 2147483647 (upper 4 digits including "-")
0 to 2147483647 (upper 4 digits)
-1073741823 to 1073741823 (upper 4 digits including "-")
-1073741823 to 1073741823 (upper 4 digits including "-")
0. to 9999., 1000 to 6553 (10000 to 65530) (times)
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours), power-on time
(hours)
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours), power-on time
(hours)
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours), power-on time
(hours)
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours), power-on time
(hours)
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours), power-on time
(hours)
Factor, frequency (Hz), current (A), voltage across P-N (V), running time (hours), power-on time
(hours)
Warning code
0.0 to 999.9 (V)
0.0 to 100.0 (%)
0.0 to 100.0 (%)
0.0, "start frequency" to "maximum frequency" (or maximum frequency,
2nd/3rd motors) (Hz)
0.0 to 100.0 (when PID function is enabled)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
00 (forward rotation), 01 (reverse rotation)
4 - 3
Chapter 4 List of Data Settings
1: Capacitor on main circuit board
2: Cooling-fan speed drop
ON
OFF
Monitored data or setting
Setting
Change
during
during
operation
operation
Default
(allowed or
(allowed or
not)
not)
Setting
Change
during
during
operation
operation
Default
(allowed or
(allowed or
not)
not)
0.00
30.00
30.00
30.00
30.00
30.00
30.00
00