WATTAGE CONSUMPTION OF EQUIPMENT

DEVICE
Air Conditioner (12,000 BTU)** ........................................................................................................................... 1700
Air Conditioner (24,000 BTU)** ........................................................................................................................... 3800
Air Conditioner (40,000 BTU)** ........................................................................................................................... 6000
Battery Charger (20 Amp) ..................................................................................................................................... 500
Belt Sander (3") .................................................................................................................................................. 1000
Chain Saw .......................................................................................................................................................... 1200
Circular Saw (6-1/2") ................................................................................................................................ 800 to 1000
Compressor (1 hp)** ........................................................................................................................................... 2000
Compressor (3/4 hp)** ........................................................................................................................................ 1800
Compressor (1/2 hp)** ........................................................................................................................................ 1400
Disc Sander (9") ................................................................................................................................................. 1200
Edge Trimmer ...................................................................................................................................................... 500
Electric Nail Gun ................................................................................................................................................ 1200
Electric Range (per element) .............................................................................................................................. 1500
Furnace Fan (3/5 hp)** ......................................................................................................................................... 875
Garage Door Opener** ............................................................................................................................... 500 to 750
Hand Drill ................................................................................................................................................. 250 to 1100
Hedge Trimmer ..................................................................................................................................................... 450
Impact Wrench ..................................................................................................................................................... 500
Jet Pump** ........................................................................................................................................................... 800
Lawn Mower ....................................................................................................................................................... 1200
Light Bulb ............................................................................................................................................................. 100
Oil Burner on Furnace .......................................................................................................................................... 300
Oil Fired Space Heater (140,000 BTU) .................................................................................................................. 400
Oil Fired Space Heater (85,000 BTU) .................................................................................................................... 225
Oil Fired Space Heater (30,000 BTU) .................................................................................................................... 150
Paint Sprayer, Airless (1/3 hp)** ........................................................................................................................... 600
Paint Sprayer, Airless (handheld) .......................................................................................................................... 150
Radio .......................................................................................................................................................... 50 to 200
Submersible Pump (1-1/2 hp)** .......................................................................................................................... 2800
Submersible Pump (1 hp)** ................................................................................................................................ 2000
Submersible Pump (1/2 hp)** ............................................................................................................................. 1500
Sump Pump** ......................................................................................................................................... 800 to 1050
Table Saw (10")** ................................................................................................................................... 1750 to 2000
Weed Trimmer ..................................................................................................................................................... 500
**Allow three times the listed watts for starting these devices.

USE OF EXTENSION CORDS

Long extension cords used to connect devices to the generator result in a loss of voltage. The longer the extension
cord, the greater the voltage loss. Refer to the chart on page 12 to help select proper cable size when using exten-
sion cords.
Damaged extension cords can cause electrical shock, resulting in serious injury or death.
• DO NOT use split, frayed or worn cords.
• ALWAYS replace damaged cords immediately.
APPROXIMATE RUNNING WATTS