Satellite Terminal System
Summary of Specifications
2.3
Environment Specifications
Temperature
Thermal Gradient
Humidity
Precipitation
Salt Fog
Sand and Dust
Altitude
Solar Radiation
ES Discharge
Shock
Vibration
Table 2-8. Converter Unit and SSPA Environmental Requirements
Parameter
Operation: -40 to 55°C (-40 to 131°F)
Survival: -50 to 75°C (-58 to 167°F)
40°C/hour
10°C/15 minute
0 to 100% relative at -40 to 55°C (-40 to 131°F)
95% at 65°C/72 hours
MIL-STD-810, Method 506.2 Proc I, 5.2 inches/hour
MIL-STD-810, Method 506.2
MIL-STD-810, Method 509.2
MIL-STD-810, Method 510.1
Operational: 0 to 15,000 ft
Survival: 0 to 50,000ft
360 BTU/ft
Operational: 10 KV
Survival: 15 KV
Operation: 10 g for 10 mS (half-sine) on three axis
Survival: 40 g for 10 mS (half-sine) on three axis
Survival – 5minute resonant dwell at four major resonances at 1 g
peak.
Survival – 2.41g
minutes/axis
5 to 100 Hz
100 to 137 Hz
137 to 350 Hz
350 to 500 Hz
500 Hz
Operational – 0.91 g
minutes/axis
Requirements
2
/hr at 50°C (122°F)
of random vibration as listed below, 10
rms
Frequency
of random vibration as listed, 10
rms
Frequency
5 to 350 Hz
350 to 500 Hz
500 Hz
2–7
MN/KST2000L.IOM
Slope
2
0
0.20 g
/Hz
-6 dB/oct
-
0
0.0107 g
-6 dB/oct
-
0
0.0052 g
Slope
0
0.0015 g
-6 dB/oct
0
0.00074 g
Revision 2
PSD
2
/Hz
2
/Hz
PSD
2
/Hz
-
2
/Hz