Distress Test *
General
The "Distress Test" function (56) permits a "distress alert" to be sent
to the LES without actually initiating a distress activity.
A Default Distress LES must be entered prior to performing the test,
see
"Selecting Default Distress
When activating the function the Distress Alarm is set in DISTRESS
TEST mode for a period of 30 seconds. The green indicator on the
Distress Alarm lights up indicating that a DISTRESS TEST will be
initiated when pressing the DISTRESS BUTTON.
To Set the Distress Alarm in DISTRESS TEST Mode:
1
Select
DISTRESS TEST function (56):
2
The default setting is REAL DISTRESS:
3
Press ENTER to set the Distress Alarm
Unit in DISTRESS TEST MODE:
Green indicator is lit on the
Distress Alarm.
4
Revert to IDLE mode:
NB! The DistressTest function automatically
reverts to REAL DISTRESS mode if not
pressing the DISTRESS BUTTON on the
Distress Alarm within the 30 seconds.
3.8
LES".
5
6
FUNC
MNO
PQR
ENTER
ENTER
3x
ESC
Saturn Bm – Chapter 3. Configuration