  • Page 2 Congratulations! You've just purchased a new Marey Power Gas tankless water heater QUICK START GUIDE and will soon begin to enjoy the benefits of “going tankless.” PACKING LIST The availability of instant hot water, combined with the unit's outstanding IMPORTANT WARNINGS...
  • Page 3 1. Water heater-Qty 1 2. Operating Instructions-Qty 1 3. Mounting Screws-4 Sets POWER GAS MODELS **WARNING: working with gas can be dangerous. If you are not familiar with local building codes and basic gas plumbing practices please employ a professional to...
  • Page 4 - Do NOT install the water heater in a sealed room or in a room with poor air 4. Low water pressure start up function: circulation. This unit requires only 8 PSI to fire, making it suitable for users with low water pressure, or those who are using it to supply hot water to upper floors.
  • Page 5 c) Install the expansion bolt into the drilled hole. Hang the unit utilizing the screws supplied. Washer The water heater must not be The water heater must not be exposed to strong wind. installed outside. Drawing 02 Drawing 03 Expansion Screw 2.
  • Page 6 Marey Heater Corporation. - The inner diameter of the water outlet pipe (including the valve) shouldn´t be less than 3/8”.
  • Page 7 - Attach the second 45 degree elbow on the other side of the wall, turning the angle - After installation is complete, open the battery compartment located at the bottom upward to run parallel with the wall. Install the second piece of flute pipe into the of the unit and install two D Cell batteries.
  • Page 8 Drawing 06 1. If a gas leak is detected at any time, close the main gas valve immediately. The Marey service center or your local gas company should be contacted for repair. 5L and 10L units 2. Before going to sleep or leaving the house, the gas supply should be shut off.
  • Page 9 The water and gas connection diagram contained on the previous page accurate 0.25 up to 0.5 PSI (NG) & 0.4 (LPG) Related Gas Pressure (PSI) only for the 5L and 10L Power Gas models. If you have a 5L or 10L unit, please Exhaust Discharge Mode Flue Duct Type follow the diagram contained on the previous page.
  • Page 10 We also strive for continuous improvement, so we welcome your comments, feedback and suggestions. 1-855-MAREY-55 customerservice@marey.com Marey proudly manufactures water heaters and accessories for use in almost any application. Please visit our website to learn more about other Marey products. Delbrey Street, 211 Not enough water flow...