4. Adjustment
4-7.

Starting the Adjustment Software

<Step 1>
Double-click on [FFW.EXE] (Fig. 4-5-3) in the folder copied to the C drive (see '4-5-1. Various downloading software
decompressions, preservation methods and notes') to display the adjustment software start-up screen.
<Step 2>
Run the adjustment in accordance with the instructions on the screen.
FinePix E500_W Adjustment Software Start-up Screen
Select [Start] from [Operate] on the FFW Toolbar
—> The adjustment software starts
—> The [Cautions When Using the Adjustment Software] screen appears.
<Step 3>
Cautions When Using the FinePix E500 Adjustment Software
1. Adjust as follows after replacing parts.
[F1]Battery [F3]LCD [F4]CCD Defect Correction [F5]Camera [F6]AF
[F7]Flash [F8]Firmware Download [F11]Video [F12]End Setting
| – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – |
| Replaced Parts
| LENS CONST : [F5]->[F4]->[F6]->[F7]->[F1]->[F12]
| SUB PWB
: [F5]>[F4]>[F6]>[F7]>[F1]>[F11]>[F3]>[F12]
| MAIN PWB
: [F7]->[F1]->[F11]->[F3]->[F12]
| STROBE
: [F7]->[F12]
| LCD
: [F3]->[F12]
|
| – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – |
2. When the SUB PWB ASSY has been replaced, always reset
the flash memory before making any other adjustments.
3. Always run End Setting after using this adjustment software.
4. Proceed with adjustment after reading the cautions here,
and the relevant cautions noted in the Service Manual.
Press the [Enter] key to proceed to the Jig Mode Setup screen.
—> The [Jig Mode Setup] screen appears.