TS-2000/X
FINAL UNIT (X45-360 A/2)
CN No. Pin No. Name I/O
CN5
1
14S
2
AGND
3
TT
4
TS
5
GND
CN9
1
14V
2
GND
3
GND
4
SPG
5
SP
6
14AG
7
14AF
8
14S
9
14S
10
8A
11
8A
12
5A
13
HFTXB
14
14TXB
15
VSF
16
VSR
17
GND
18
NC
CN10
1
GND
2
TT
3
TS
4
PSC
5
BOVR
6
THHF
7
PHD
8
AMD
124

TERMINAL FUNCTION

Function
O Switched 14V for external antenna
tuner option
-
Analog GND
I/O External antenna tuner (AT-300)
in/through control
I/O External antenna tuner (AT-300)
tuning start control
-
GND
O Constantly 14V
-
GND
-
GND
-
GND for internal speaker
I
Audio output for internal speaker
O GND for audio IC
O Power supply for audio IC
O 14V when the power switch on
O 14V when the power switch on
O 8V when the power switch on (analog)
O 8V when the power switch on (analog)
O 5V when the power switch on (analog)
I
HF-50MHz TXB
I
144MHz TXB
O Forward wave detection voltage
of HF-144MHz VSWR
O Reflected wave detection voltage
of HF-144MHz VSWR
-
GND
-
NC
-
GND
I/O External antenna tuner (AT-300)
in/through control
I/O External antenna tuner (AT-300)
tuning start control
I
Power on switch control.
"H" for power on
O Over voltage detection signal, if the
power supply voltage increases more
than approx. 19V.
Then BOVR becomes "L"
O Thermistor detection voltage.
This voltage controls fan speed
O Output voltage of phase detector in
Filter unit
O Output voltage of amplitude detector
in Filter unit
CN No. Pin No. Name I/O
9
14D
O Constantly 14V for digital circuit
10
8D
O 8V when the power switch on (digital)
11
10A
O 10V when the power switch on (analog)
12
8A
O 8V when the power switch on (analog)
13
DATA
I
Serial data
14
CLK
I
Serial clock
15
REN1
I
Enable for IC205
16
REN2
I
Enable for IC801, 802, 803
CN15
1
NC
-
NC
2
GND
-
GND
3
50RL
O 50MHz TX LPF relay control.
"H" for LPF active
4
10RL
O 10MHz TX LPF relay contro.
"H" for LPF active
5
28RL
O 28MHz TX LPF relay control.
"H" for LPF active
6
7RL
O 7MHz TX LPF relay control.
"H" for LPF active
7
21RL
O 21MHz TX LPF relay control.
"H" for LPF active
8
14RL
O 14MHz TX LPF relay control.
"H" for LPF active
9
4RL
O 3.5MHz TX LPF relay control.
"H" for LPF active
10
2RL
O 1.8MHz TX LPF relay control.
"H" for LPF active
11
144RL
O 144MHz TX/RX relay control. "H" for TX
12
NC
-
NC
CN16
1
VSF
I
Forward wave detection voltage
of HF-50MHz, comes from Filter unit
then combine with 144MHz VSF
2
VSR
I
Reflected wave detection voltage
of HF-50MHz, comes from Filter unit
then combine with 144MHz VSR
3
PHD
I
Output voltage of phase detector in
Filter unit, which passes through Final
unit then goes to control unit
4
AMD
I
Output voltage of amplitude detector
in Filter unit, which passes through
Final unit then goes to control unit
5
5A
O 5V when the power switch on (analog)
6
HFRL
O HF TX/RX antenna changeover relay
control, "H" for TX
7
ATS
O Internal antenna tuner in/through
changeover relay control, "H" for
antenna tuner input