Kenwood TS-2000 Service Manual page 115

All mode multi-band transceiver
Hide thumbs Also See for TS-2000:
Table of Contents

Advertisement

TS-2000/X
Item
Condition
19. UHF
1) Menu No. : 101
power POC
Display f. : 438.1MHz
50W/20W
Mode : USB
Transmit
25W/10W
2) Menu No. : 102
Transmit
12.5W/5W
3) Menu No. : 103
Transmit
5W/1W
4) Menu No. : 104
Transmit
20. UHF band
1) Menu No. : 105
TGC
Display f. : 438.1MHz
Mode : USB
Transmit
21. UHF
1) Menu No. : 106
power PGC
Display f. : 438.1MHz
25W/10W
Mode : USB
Transmit
12.5W/5W
2) Menu No. : 107
Transmit
5W/1W
3) Menu No. : 108
Transmit
22. ALC meter 1) Menu No. : 87
start point
Display f. : 14.1MHz
Mode : USB
Transmit
Zone max.
2) Menu No. : 88
Transmit
23. FM DEV
1) Menu No. : 89
Wide
Display f. : 29.1MHz
Mode : FM
Transmit
Narrow
2) Menu No. : 90
Transmit
24. HF SWR
1) Menu No. : 118
protection
Display f. : 14.1MHz
Mode : CW
Transmit
150Ω dummy connection
: Use a cable that is 1m long
25. SWR meter 1) Menu No. : 119
(SWR : 3)
Display f. : 14.1MHz
Mode : FM
Transmit
150Ω dummy connection
: Use a cable that is approx. 10cm long
26. 50MHz
1) Menu No. : 120
SWR meter
Display f. : 50.1MHz
(SWR : 3)
Mode : CW
Transmit
116
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT430 Front
panel
panel
ANT1
Through type Rear
ANT2
power meter panel
150Ω dummy
Adjustment
Parts
Method
[+] key Set the adjustment
50W±2W
or
value within the
[–] key limit of the specified
power.
25W±1W
12.5W± 0.5W
5W± 0.3W
50W±2W
25W±2W
12.5W± 0.5W
5W± 0.3W
[+] key 1 push
(ALC meter lights up to 1)
(ALC meter zone max.)
4.3kHz±0.05kHz
2.2kHz±0.05kHz
[+] key Set the adjustment
40W±1W
or
value within the
[–] key limit of the specified
power.
[+] key 1 push