Horizontal Terminations With Two 90° Elbows; Approved Venting Configurations With A Horizontal Termination - Travis Industries Avalon Cedar User Manual

Direct vent freestanding stove
Table of Contents

Advertisement

Installation
12

Approved Venting Configurations with a Horizontal Termination

and Two Elbows (
If using a Snorkel Termination (14" or 36") add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
19' (max)
15 feet
10' (min)
5 feet
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
Travis Industries
one 90° vertical and one 90° or 45° horizontal elbow
Restrictor
Position # 1
NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.
NATURAL GAS: Min. 2' Section Required
PROPANE (LP): Min. 3' Section Required
H1
4 0 3 0 2 0 6
(for qualified installers only)
Restrictor
Position # 5
NOTE:
Restrictor positions are based upon lab
tests. The ideal restrictor position may vary
slightly, especially when the termination is
near a demarkation line.
H2
Horizontal length (max. 24') is calculated
by adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbows
)
19' (max)
15 feet
10' (min)
5 feet
0 feet
9 3 5 0 8 1 1 7