Operation Section
G420F Engine and G424F Engine and G424I Engine
EMS (Engine management system) of G420F engine and G424F engine and G424I engine is an open loop
LP system and/or closed loop gasoline system. 3-way catalytic muffler is not used for this system.
LPG regulator and the mixer are operated in open loop as no mixture adjustments are made by the SECM.
Manifold pressure from the TMAP, rpm from the crank position sensor and throttle position is used by the
SECM to calculate load. Feedback from the electronic throttle is still provided to the SECM by the throttle
position sensors (TPS).
EMS schematic of G420F / G424F / G424I Dual Fuel engine