DIAGNOSTIC TROUBLE CODE (DTC) CHART – SORTED BY DTC # (4 of 4)
Description
DTC 2618: Tach output ground short
DTC 2619: Tach output short to power
DTC 8901: UEGO microprocessor internal fault
DTC 8902: UEGO heater supply high voltage
DTC 8903: UEGO heater supply low voltage
DTC 8904: UEGO cal resistor voltage high
DTC 8905: UEGO cal resistor voltage low
DTC 8906: UEGO return voltage shorted high
DTC 8907: UEGO return voltage shorted low
DTC 8908: UEGO pump voltage shorted high
DTC 8909: UEGO pump voltage shorted low
DTC 8910: UEGO sense cell voltage high
DTC 8911: UEGO sense cell voltage low
DTC 8912: UEGO pump voltage at high drive limit
DTC 8913: UEGO pump voltage at low drive limit
DTC 8914: UEGO sense cell slow to warm up
DTC 8915: UEGO pump cell slow to warm up
DTC 8916: UEGO sense cell impedance high
DTC 8917: UEGO pump cell impedance high
DTC 8918: UEGO pump cell impedance low
DTC Set 2
SPN-2
FMI-2
645
4
645
3
3221
31
3222
3
3222
4
3221
3
3221
4
3056
3
3056
4
3218
3
3218
4
3217
3
3217
4
3225
3
3225
4
3222
10
3225
10
3222
0
3225
0
3225
1