FLUE CONFIGURATIONS

HORIZONTALE FLUE
Maximum flue index : 60 Pa.
This value is reached when L exceeds 3 m
(include elbow)
VERTICAL CONCENTRIC FLUE Ø 80 / 125 mm
Maximum flue index : 60 Pa.
This value is reached when the vertical flue L
exceeds 7,5 m (include adapter)
Important : remove the flue restrictor ring when
(L) exceeds 4 m.
TWIN PIPE FLUE 2 x Ø 80 mm
L 1
L
Important : remove the flue restrictor ring
when (L) exceeds 1 m.
Maximum flue index : 60 Pa.
This value is reached when (L1) + (L2) exceeds
L 2
11 m (includes elbows and terminal).
The flue must be fitted with a minimum slope of
35 mm per metre towards the terminal.
L
Important : remove the flue
restrictor ring when (L1) + (L2)
exceeds 8 m.
slope of 35 mm
per metre