TECHNICAL DATA

Refer to the data badge for exact type of appliance
and the gases it is suitable for.
Variable output of
Efficiency
Minimum flow rate, hot water temperature to :
maxi. position
mini. position
Maximum flow rate (by flow limiter)
Specific flow rate (∆t 30 °C)
Minimum water pressure
Maximum water pressure*
Max hot water temperature
Venting of flue gases via flue system
Incoming fresh air via flue system
Supply voltage
Current
Power
Electrical protection
* These maximum water pressure values take into account
the dilation of the water.

WATER HEATER INSTALLATION

This appliance must be installed in accordance with
the current issue of :
The gas safety (installation and use) regulations
The building regulations
The local water company byelaws
The building standards regulations (Scotland)
The health and safety at work act.
The gas safety (installation and use) regulations : it is
the law that all gas appliances are installed by
competent persons in accordance with the above
regulations. Failure to install appliances correctly
could lead to prosecution. It is in your own interest,
and that of safety, to ensure the law is complied
with.
  
245 mini
3%
61,6
100
100
GAZ
EC
EF
17
17
141
141
100 mm
100 mm
4
8,7 kW (29665 Btu/h)
to 22,7 kW (77403 Btu/h)
78,4 %
2,7 l/min (0,60 g/min)
4,2 l/min (0,92 g/min)
3 l/min (2,86 g/min)
11 l/min (2,42 g/min)
[pw] 0,3 bar (4,50 Ib/in
[pw] 10 bar (150 Ib/in
60 °C
Ø 60 mm
Ø 100 mm
230 V
0,31 A
55 W
IP 44
Ø 105
50
mini
Gas Category : II
Natural (G 20) (ref. 15 ° C and 1013 mbar)
Ø buner injector
Appliance Inlet pressure
Max. gas flow rate output
Min. gas flow rate
Butane (G 30)
Ø buner injector
Appliance Inlet pressure
2
)
Max. gas flow rate output
2
)
Min. gas flow rate
Propane (G 31)
Ø buner injector
Appliance Inlet pressure
Max. gas flow rate output
Min. gas flow rate
Only a qualified technician is authorized to intervene on
sealed mechanisms.
LOCATION
When determining the siting of the water heater,
make sure you keep an approx. distance of 50 mm
between the sides of the appliance to ensure total
accessibility for servicing.
The jig will enable you to determine the position of
the flue system hole at the top outlet. All informa-
tion regarding the installation of the flue system is
provided in the flue system package.
If the water-heater is not fitted straight away, the
water and gas fittings must be protected from
contaminents E.G. plaster, paint.
PIPE FITTINGS : Gas Manual gas cock 3/4" F - 1/2" M
Cold water inlet : stop cock 3/4" F - 1/2 " M with
angled tail
DHW outlet : 3/4" F - 1/2 " M angled tail
100 100
GAS
GAZ
AC
EC
141
.
2H3+
28 - 30 mbar
AF
EF
86
103
141
1,20 mm
20 mbar
3
2,75 m
/h
1,13 m
3
/h
0,80 mm
2,04 kg/h
0,83 kg/h
0,80 mm
37mbar
2,02 m
3
/h
3
0,82 m
/h