Advertisement

WATER HEATERS
I N W A R R A N T Y
T E C H N I C A L H E L P L I N E
01773 828400
01773 828100
THESE ARE CAT II2H3+ APPLIANCE
1

Advertisement

Table of Contents
loading

Summary of Contents for Saunier Duval OPALIS 6

  • Page 1 WATER HEATERS I N W A R R A N T Y T E C H N I C A L H E L P L I N E 01773 828400 01773 828100 THESE ARE CAT II2H3+ APPLIANCE...
  • Page 2: Table Of Contents

    The identification plate located on the inside of the appliance certifies the origin where the product was manufactured and the country for which it is intended. If you see any exception to this rule, please contact your nearest Saunier Duval dealer. Thank you in advance for your assistance.
  • Page 3: Introduction

    The OPALIS 6 models are fitted with a flue safety device that shuts off the appliance in the event of The water heaters are gas-fired appliances pro- a problem with the flue system.
  • Page 4: Dimensions

    : 8,5 Kg Various size spouts are available. Please contact your supplier. Gross weight : 9 Diagram 1.1 Diagram 1.2 OPALIS 5 OPALIS 6 Ø 83 618 x 280 x 180 482 x 280 x 180 TECHNICAL DATA Model Input...
  • Page 5 TECHNICAL DATA OPALIS 6 Output [P] ............... 9,65 (32905 Btu/h) Efficiency ................Minimum flow rate ................l/min (0.6 g/min) Maximum flow rate ................l/min (1.3 g/min) Minimum water pressure [pw] ..............(9 lb/in Maximum water pressure ( ) [pw] ..............
  • Page 6: Heater Schematic

    HEATER SCHEMATIC SCHEMATIC DIAGRAM A1 ....draught diverter Diagram 2.1 A3 ....heat exchanger A4 ....burner OPALIS 6 B ....... gas mechanism C ...... water mechanism E1 ..... thermocouple E2 ..... flue safety device 1 ..... pilot 2 ..... user control 3 .....
  • Page 7: Installation Requirements

    INSTALLATION REQUIREMENTS This appliance must be installed in accordance Specific conditions for the Opalis 5 with the latest issue of the following : Under no circumstances must a flueless water BS 5440 : Part 1 flues. Flues and air supply for gas heater be installed in a bathroom, shower room, appliances of rated input not exceeding 60 kW.
  • Page 8: Water Heater Installation

    WATER HEATER INSTALLATION LOCATION Diagram 3 Avoid installing the appliance in a room in which the air is corrosive or dusty. Avoid installing the appliance in close proximity to a cooking appliance. crochet de Position The recommended height to install the appliance of support hook fixation is 1.5 m (59 in) from the viewing window to the...
  • Page 9: Commissioning & Lighting - Opalis 6

    COMMISSIONING & LIGHTING - OPALIS 6 Commissionning Diagram 5 With the front casing removed, fit the temperature selector knob where applicable. OPALIS 6 On tap models, fit the hot tap handle (red) to the left hand spindle and the cold tap handle (blue) to the right hand spindle.
  • Page 10: Commissioning & Lighting - Opalis 5

    COMMISSIONING & LIGHTING - OPALIS 5 Commissionning Diagram 7 With the front casing removed, fit the tempera- ture selector knob where applicable. OPALIS 5 On tap models, fit the hot tap handle (red) to the left hand spindle and the cold tap handle (blue) to the right hand spindle.
  • Page 11: Adjustments

    The flow rate of the hot water is adjustable : — for the OPALIS 6 : between 2.7 l/mn with an increase of 50 °C and 6 l/ mn with an increase of 25 °C.
  • Page 12: Safety Devices

    OPALIS 6 MODELS The heater is fitted with a flue safety device. In the appliance. event of total or partial obstruction of the flue...
  • Page 13: Servicing / Maintenance - Opalis 6

    SERVICING / MAINTENANCE - OPALIS 6 Diagram 10 1 - Pilot tube 2 - Temperature selector 3 - Pilot tube clip 4 - Pilot injector To ensure the continued efficient and safe operation of the water heater, it is recommended that it is checked and serviced annually.
  • Page 14: Servicing / Maintenance - Opalis 5

    SERVICING / MAINTENANCE - OPALIS 5 Diagram 11 1 - Pilot tube 2 - Temperature selector 3 - Pilot injector 4 - Upper pilot injector 5 - Fastening tube/burner support screw 6 - Blockage safety tube 7 - Thermocouple solenoid 8 - Pilot earth screw 9 - Brass tube mechanism/pilot connection lift pilot until pilot tube (1) slips out of brass tube...
  • Page 15: Draining

    Ever anxious to improve the quality of its appliances, the Saunier Duval/ hot water/ heater company reserves the right to modify the latter without prior notice. The technical information contained in our documents are given for guidance only and are without liability.
  • Page 16 104560 B 07/96...

This manual is also suitable for:

Opalis 5

Table of Contents