Faults And Solutions - Ariston 60 cm Service Manual

Table of Contents

Advertisement

5.4 LED INDICATED FAULTS AND SOLUTIONS:
Legend: 1 = LED 1; 2 = LED 2; 3 = LED 3;
Reading of faults shown by LEDs
The control panel LEDs light up, to signal the fault, according to the following table (the LEDs stay on while
the fault lasts).
Faults
F01
F02
F03
F04
F05
F06
F07
F08
F09
F12
F14
F21
F22
F23
F24
F25
Table. Led Faults Blocking Faults
Service Manual
NEW ARISTON 60 cm PLATFORM
1
2
LED 1
off
on
off
on
Flashing
on
off
Flashing
Flashing
off
on
on
Flashing
Flashing
off
on
3
Signal
LED 2
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
off
off
on
on
on
on
off
Non-blocking Faults
Edition
2006.06.15
LED 3
off
off
on
on
on
Flashing
Flashing
off
Flashing
on
on
Flashing
on
Flashing
Flashing
Flashing
Language
English
E
N
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mbt2022cz

Table of Contents