Duration of Autotest procedure: 255 seconds.
Test sequence:
The probes are tested for the first 5 seconds of the procedure. 10 seconds after
Autotest activation, the freezer fan switches on and runs until the end of the
procedure.
Fault signalling:
Fault signalling: Any faults are signalled by a specific combination of leds on the
interface. In the event of Probe faults, the fridge lamp will also flash.
Model: COMBI STATIC TOUCH with CCZ
Duration of Autotest procedure: 255 seconds.
Test sequence:
The probes are tested for the first 5 seconds of the
procedure. 10 seconds after Autotest activation,
the freezer fan switches on and runs until the end of
the procedure.
Fault signalling:
Any faults are signalled on the fridge and freezer
displays (e.g. F01). In the event of Probe faults, the
fridge lamp will also flash.
Model: COMBI NO-FROST TOUCH with CCZ and Ever Fresh
Duration of Autotest procedure: 255 seconds.
Test sequence:
The probes are tested for the first 5 seconds. 10
seconds after Autotest activation, the freezer fan
and defrost elements switch on and remain in
operation until the end of the test. 10 seconds after
activation of the Autotest, the electronic damper is
opened for 125 seconds and then closes again at the
end of the autotest. 10 seconds after activation of
the Autotest, the electronic damper in the variable
temperature compartment is opened for 125
seconds and then closes again at the end of the
autotest.
Fault signalling:
Any faults are signalled on the fridge and freezer
displays (e.g. F01). In the event of Probe faults, the
fridge lamp will also flash.
Service Manual
NEW ARISTON 60 cm PLATFORM
Edition
2006.06.15
E
Language
English
N
26