5.3 AUTOTEST SEQUENCE:
Model: ELECTRONIC THERMOSTAT
Duration of Autotest procedure: 255 seconds.
Test sequence: 1. test defrosting element (8 seconds) pause 3 seconds
2. test freezer air probe (8 seconds) pause 3 seconds
3. test freezer fan (8 seconds) pause 3 seconds
4. Element and fan on for approx. 230 seconds.
Fault signalling:
After each step the appliance light switches on steady
to indicate that the test detected no faults, or flashing
to indicate faults.
Note. do not forget the important points for correct autotest sequence
(e.g.: the Freezer compartment temperature must be below -10°C).
Model: COMBI NO-FROST BASIC
Duration of Autotest procedure: 255 seconds.
Test sequence:
The probes are tested for the first 5 seconds. 10 seconds after Autotest activation,
the freezer fan and defrost elements switch on and remain in operation until the end
of the test. 10 seconds after activation of the Autotest, the electronic damper is
opened for 125 seconds and then closes again at the end of the autotest.
Fault signalling:
Any faults are signaled by a specific combination of leds on the interface. In the
event of Probe faults, the fridge lamp will also flash.
Model: COMBI STATIC BASIC
Duration of Autotest procedure: 255 seconds.
Test sequence:
The probes are tested for the first 5 seconds of the procedure. 10 seconds after
Autotest activation, the freezer fan switches on and runs until the end of the
procedure.
Fault signalling:
Any faults are signalled by a specific combination of leds on the interface. In the
event of Probe faults, the fridge lamp will also flash.